DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off for Foundry
Prime robots!)
to the robot, before entering the robot working area.
1
Check regularly that the stop pin is not bent or dam-
aged in any other way.
2
Removal/refitting of the
mechanical stop is detailed in
section
.
Note
If the mechanical stop pin has been deformed or
damaged, it must be replaced by a new one!
3
Also check that the stop pin is properly attached.
4
Product manual - IRB 4400
105
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
3 Maintenance
3.4.3 Inspection of mechanical stop, axis 1