114 Appendix A – CANopen Object Dictionary
1030
0
Interface
Group
U8
R
9
Number of entries
1
Interface
Index
U32
R
-
Interface index of the physical
interface.
Always 1.
2
Interface
Description
VSTR
R
-
Textual string containing
information about the interface
3
Interface
Type
U8
R
6
1 = Other
6 = Ethernet CSMA/CD
7 = iso88023 CSMA/CD
Always 6 (Ethernet CSMA/CD)
4
Interface
MTU
U16
R
-
Size of the largest datagram
which can be sent/received on
the interface, specified in
octets
5
Interface
Phys Address
OSTR
R
-
MAC address assigned during
manufacturing
6
Interface
Name
VSTR
R
-
Always eth0
7
Interface
Operation
Status
U8
R
-
The current operational state
of the interface
0 = Down
1 = Up
8
Interface
Admin State
U8
RW
1
The current administration
state of the interface
0 = Down
1 = Up
9
Valid Boolean
BOOL
RW
FALSE Specifies whether or not the
data of this object is valid.
TRUE = The data is valid.
FALSE = The data is invalid.
1300
0
SDO
sequence
timeout
U32
RW
-
Timeout value in milliseconds
for the connection abort
recognition of the SDO
sequence layer
Index
SI
Name
Type
Acc.
Def.
Information
Содержание FEPL-02 Ethernet POWERLINK
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 20: ...20 About the manual ...
Страница 28: ...28 Mechanical installation ...
Страница 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Страница 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Страница 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Страница 90: ...90 Communication profiles ...
Страница 100: ...100 Communication protocol ...
Страница 104: ...104 Diagnostics ...
Страница 108: ...108 Technical data ...
Страница 140: ...140 Appendix C IdentResponse Frame ...