Start-up 43
Speed and torque control using ABB Drives
communication profile
This example shows how to configure a speed and torque control
application that uses the ABB Drives profile. In addition, some
application-specific data is added to the communication.
The start/stop commands and references are according to the ABB
Drives profile. For more information, see the state machine on
.
When reference 1 (REF1) is used, reference value ±20000
(decimal) corresponds to the reference set with parameter 1105
REF1 MAX in the forward and reverse directions.
When reference 2 (REF2) is used, a reference value of ±10000
(decimal) corresponds to the reference set with parameter 1108
REF2 MAX in the forward and reverse directions.
The minimum and maximum 16-bit integer values that can be
given through the fieldbus are -32768 and 32767 respectively.
When configuring the master, you need to map the following
objects to the transmit and receive PDOs. For an example, see
section
Mapping objects required for controlling the drive
page
.
The table below gives the recommended drive parameter settings.
CANopen
object
Output data
CANopen
object
Input data
0x2101
Control word
0x2104
Status word
0x2102
Speed reference
0x2105
Speed actual value
0x2103
Torque reference
0x2106
Torque actual value
Drive parameter
Setting for ACS355
drives
Description
9802 COMM PROT SEL
4
= EXT FBA
Enables communication between
the drive and the fieldbus adapter
module.
5101 FBA TYPE
136
= ETH Pwrlink
1)
Displays the type of the fieldbus
adapter module.
5102 FB PAR 2
(PROFILE)
1
(= ABB Drives
profile)
Selects the ABB Drives profile.
Содержание FEPL-02 Ethernet POWERLINK
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 20: ...20 About the manual ...
Страница 28: ...28 Mechanical installation ...
Страница 63: ...Start up 63 2 To add the adapter module right click the IF3 list entry and then click Insert ...
Страница 69: ...Start up 69 3 In the Project transfer dialog box click OK 4 Wait for the transfer to finish ...
Страница 70: ...70 Start up When the transfer is finished the PLC starts up in the RUN mode ...
Страница 90: ...90 Communication profiles ...
Страница 100: ...100 Communication protocol ...
Страница 104: ...104 Diagnostics ...
Страница 108: ...108 Technical data ...
Страница 140: ...140 Appendix C IdentResponse Frame ...