PROFINET IO – Start-up 273
50.05 FBA REF2
MODESEL
Velocity
Selects the fieldbus reference 2
scaling.
51.01 FBA TYPE
ETHERNET
1)
Displays the type of the fieldbus
adapter module.
51.02 FBA PAR2
(PROTOCOL/PROFILE)
14
(= PNIO PdriveM) Selects the PROFINET IO protocol
and PROFIdrive positioning mode.
51.03 FBA PAR3
(COMMRATE)
0
(= Auto
2)
Ethernet communication rate is
negotiated automatically by the
device.
51.04 FBA PAR4
(IP CONFIGURATION)
0
(= Static IP)
Configuration will be obtained from
parameters
05
...
13
or from the PLC
via the DCP protocol.
52.01 FBA DATA IN1
4
(= SW 16bit)
1)
Status word
52.02 FBA DATA IN2
15
(= Act1 32bit)
Actual value 1
52.04 FBA DATA IN4
16
(= Act2 32bit)
Actual value 2
53.01 FBA DATA OUT1
1
(= CW 16bit)
1)
Control word
53.02 FBA DATA OUT2
12
(= Ref1 32bit)
Reference 1
53.04 FBA DATA OUT4
13
(= Ref2 32bit)
Reference 2
51.27 FBA PAR
REFRESH
REFRESH
Validates the FENA-11/-21
configuration parameter settings.
10.01 EXT1 START
FUNC
FBA
Selects the fieldbus interface as the
source of the start and stop
commands for external control
location 1.
10.05 JOG ENABLE
C.FALSE
Disables the jogging functions.
22.01 SPEED FB SEL
Enc1 speed
2)
Selects the actual speed measured
by encoder 1 as the speed
feedback.
34.02 EXT1 MODE
1/2SEL
P.FBA MAIN CW.26
Selects the source for external 1
control mode 1/2 selection.
Selection is done by
START_HOMING bit (bit 26 in the
fieldbus Control word).
Mode 1: Position, Mode 2: Homing
34.03 EXT1 CTRL
MODE1
Position
Selects position control as the
control mode 1 for external control
location 1.
Drive parameter
Setting for ACSM1
drives
Description
Содержание FENA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FENA 01 11 21 Ethernet adapter module ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 32: ...32 Introduction to the manual ...
Страница 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Страница 42: ...42 Mechanical installation ...
Страница 46: ...46 Electrical installation ...
Страница 48: ......
Страница 94: ...94 Modbus TCP Communication profiles ...
Страница 106: ...106 Modbus TCP Communication protocol ...
Страница 112: ...112 Modbus TCP Diagnostics ...
Страница 114: ......
Страница 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Страница 180: ...180 EtherNet IP Communication profiles ...
Страница 246: ......
Страница 297: ...PROFINET IO Start up 297 4 Click and drag the FENA object from the device catalog to the Ethernet 1 PROFINET IO System ...
Страница 304: ...304 PROFINET IO Start up ...
Страница 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...