196 EtherNet/IP – Communication protocol
ABB Drives profile with set speed assembly
The ABB Drives profile with set speed assembly is defined by
ABB. The format of the output assembly is:
The format of the input assembly is:
Instance 1 (ABB Drives profile)
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reset Ramp
in
Zero
Ramp
Hold
Ramp
Out
Zero
Inhibit
Oper-
ation
Off 3
Control
Off 2
Control
Off 1
Control
1
Ext
Ctrl
Loc
Remote
Cmd
2
Set Speed (Low Byte)
3
Set Speed (High Byte)
Instance 51 (ABB Drives profile)
Byte Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Alarm Swc
On
Inhib
Off 3
Sta
Off 2
Sta
Tripped Rdy
Ref
Rdy
Run
Rdy
On
1
Field-
bus
Error
Ext
Run
Enable
Ext Ctrl
Loc
Above
Limit
Re-
mote
At Set-
point
2
Actual Speed (Low Byte)
3
Actual Speed (High Byte)
Содержание FENA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FENA 01 11 21 Ethernet adapter module ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 32: ...32 Introduction to the manual ...
Страница 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Страница 42: ...42 Mechanical installation ...
Страница 46: ...46 Electrical installation ...
Страница 48: ......
Страница 94: ...94 Modbus TCP Communication profiles ...
Страница 106: ...106 Modbus TCP Communication protocol ...
Страница 112: ...112 Modbus TCP Diagnostics ...
Страница 114: ......
Страница 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Страница 180: ...180 EtherNet IP Communication profiles ...
Страница 246: ......
Страница 297: ...PROFINET IO Start up 297 4 Click and drag the FENA object from the device catalog to the Ethernet 1 PROFINET IO System ...
Страница 304: ...304 PROFINET IO Start up ...
Страница 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...