258 PROFINET IO – Start-up
FENA-01/-11/-21 configuration parameters – group B (group 2)
Note:
The actual parameter group number depends on the drive
type. Group B (group 2) corresponds to:
•
parameter group 55 in ACS355
•
parameter group 53 in ACSM1, ACS850 and ACQ810
•
parameter group 53 in ACS880 and ACS580 if the adapter is
installed as fieldbus adapter A or group 56 if the adapter is
installed as fieldbus adapter B.
No.
1)
Name/Value
Description
Default
01
DATA OUT 1
(master to drive)
Selects data word 1 received by the drive over
the PROFINET network. The content is defined
by a decimal number in the range of 0 to 9999
as follows:
See also
Virtual address area allocation with
ACSM1
on page
261
.
1 or 11
2)
ACS355:
FBA DATA OUT 1
ACSM1:
FBA DATA OUT1
ACS850/ACQ810:
FBA data out1
ACS880/ACS580:
FBA A/B data out1
0
= None
Not used
1
= CW 16bit
Control word (16 bits)
3)
2
= Ref1 16bit
Reference REF1 (16 bits)
3)
3
= Ref2 16bit
Reference REF2 (16 bits)
3)
11
= CW 32bit
Control word (32 bits)
12
= Ref1 32bit
Reference REF1(32 bits)
13
= Ref2 32bit
Reference REF2 (32 bits)
21
= CW2 16bit
Control word 2 (16 bits)
101…9999
Parameter index with format
xxyy
, where
•
xx
is the parameter group number (1…99)
•
yy
is the parameter number index within
that group (01…99).
Note:
In ACS880 and ACS580, choose
Other
to display a list of mappable drive parameters.
0
Not used
1…99 Virtual address area of drive control
101…
9999
Parameter area of the drive
Содержание FENA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FENA 01 11 21 Ethernet adapter module ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 32: ...32 Introduction to the manual ...
Страница 38: ...38 Overview of the Ethernet network and the FENA 01 11 21 module ...
Страница 42: ...42 Mechanical installation ...
Страница 46: ...46 Electrical installation ...
Страница 48: ......
Страница 94: ...94 Modbus TCP Communication profiles ...
Страница 106: ...106 Modbus TCP Communication protocol ...
Страница 112: ...112 Modbus TCP Diagnostics ...
Страница 114: ......
Страница 154: ...154 EtherNet IP Start up 3 In the Select Module window select ETHERNET MODULE ...
Страница 180: ...180 EtherNet IP Communication profiles ...
Страница 246: ......
Страница 297: ...PROFINET IO Start up 297 4 Click and drag the FENA object from the device catalog to the Ethernet 1 PROFINET IO System ...
Страница 304: ...304 PROFINET IO Start up ...
Страница 374: ...374 AppendixA PROFIdriveparametersandI MrecordsofPROFINETIO ...