2CCF018900R0002-CH | AC Charger for Electric Vehicles, Model eCharger 43
8 Signals
IMPORTANT (ADVICE)
The output signals of the LED-display and the LED-button (LED in the button “Start”) show the state of the
system and possibly existing problems.
The information for the troubleshooting of faults is intended for the use by qualified staff.
Abb. 32: Red LEDs indicate error
LED
Description—Solution
Green
Ready to charge
Blue
Charging at maximum speed
Blue/Red
Charging at reduced speed due to ambient
temperature
Red 1x
RCD fault—contact local electrician
Red 2x
Charging station blocked—contact local operator
Red 3x
Detected card id unknown—Register at abb.e-
track2.nl
Red 4x
Detected card id for transaction stop mismatch
Red 5x
Card not accepted because customer is blocked
Red 6x
PP value underrated—try another charging cable
Red 7x
State D (lead battery) detected— This is not supported
Red 8x
CP state unknown—try another charging cable
Red 9x
CP diode not detected—try another charging cable
Red 10x
PP state unknown—try another charging cable
Red 11x
Boot process active—please wait...
Red 12x
Generic error—contact support
Red 13x
CP not connected (state A)
Red 14x
PP not connected
Red 15x
Lock failed
Red 16x
Serial KWH meter fault
Red 17x
Fuse tripped
Red 18x
Second RCD tripped—contact local electrician
Red 19x
Relay fault—contact local electrician
Red 20x
Card expired —contact local operator
Red 21x
Cable reconnect detected—not allowed