2CCF018900R0002-CH | AC Charger for Electric Vehicles, Model eCharger 41
7 Technical
Data
IMPORTANT (REMARK)
The charging station has an internal residual current protection (RCD). The included miniature circuit
breaker (MCB) only protects the control electronics. Circuit breakers need to be foreseen in every
normal installation at the sub distribution box outside the charging device.
Phases 1-phase
charging
3-phase charging
3-phase charging
Current 16A
16A
32A
eCharger single
CUA2-F1T2L-16M3,
CUA2-W1T2L-16M3
CUA4-F1T2L-16M3,
CUA4-W1T2L-16M3
CUA4-F1T2L-32M3,
CUA4-W1T2L-32M3
eCharger double
CUA2-F2T2L-16M3,
CUA2-W2T2L-16M3
CUA4-F2T2L-16M3,
CUA4-W2T2L-16M3
-
Electrical Data
Electrical Connection,
eCharger single
230V AC, 50-60 Hz,
16A, 1-phase, N, PE
400V AC, 50-60 Hz,
16A, 3-phases, N, PE
400V AC, 50-60 Hz,
32A, 3-phases, N, PE
Electrical Connection,
eCharger double
400V AC 50-60 Hz,
16A, 3-phase, N, PE
2 power cables, 2MCBs,
each 400 V AC 16A,
50-60 Hz, 3-phases
-
Permissible connection
cross-section, single
Min. 3x2.5mm
2
Cu
Max. 3x10mm
2
Cu
Min. 5x2.5mm
2
Cu
Max. 5x10mm
2
Cu
Min. 5x6mm
2
Cu
Max. 5x10mm
2
Cu
Permissible connection
cross-section, double
Min. 5x2.5mm
2
Cu
Max. 5x10mm
2
Cu
Each power cable
Min. 5x2.5mm
2
Cu
Max. 5x10mm
2
Cu
-
Suggested Circuit
breaker device (not
included), eCharger
single
S 202 M-C 16
2CDS272001R0164
optional:
S201-C 16 NA
2CDS251103R0164
S 204 M-C 16
2CDS274001R0164
optional:
S203-C 16 NA
2CDS253103R0164
S 204 M-C 32
2CDS274001R0324
optional:
S203-C 32 NA
2CDS253103R0324
Suggested Circuit
breaker device (not
included), eCharger
double
1 pc. S 204 M-C 16
2CDS274001R0164
optional:
1 pc. S203-C 16 NA
2CDS253103R0164
2 pcs. S 204 M-C 16
2CDS274001R0164
optional:
2 pcs. S203-C 16 NA
2CDS253103R0164
-
Max. power per charger,
single
3.7 kW
11 kW
22 kW
Max. power per charger,
double
2 x 3.7kW = 7.4 kW
2 x 11kW = 22 kW
-
Residual current
protection (per outlet)
Residual Current Device,
30mA Type A,
shorttime delayed
Residual Current
Device 30mA
Type B,
shorttime delayed
Residual Current Device
30mA
Type B,
shorttime delayed
Charging Points
Number of charging
points, single
1 socket
1 socket
1 socket
Number of charging
points, double
2 sockets
2 sockets
-
Rated voltage per output
230V AC, 1 phase
400V AC, 3-phases
400V AC, 3-phases
Charging current
max. 16A
max. 16A
max. 32A
Max. power per outlet
max. 3.7kW
max. 11kW
max. 22kW
Socket
IEC 62196 "Mennekes" Type 2, 7-pole, electromechanic interlock
Charging mode
Mode 3
Mechanical Data
Enclosure
aluminium
Содержание eCharger CUA2-F1T2L-16M3
Страница 44: ...44 2CCF018900R0002 CH AC Charger for Electric Vehicles Modell CU Annex A CE Declaration of Conformity ...
Страница 54: ......
Страница 55: ......