17
3ADW000191R0500 DCS800 Quick guide edisf e
1. General
In operation, drive converters, depending on their degree of
protection, may have live, uninsulated, and possibly also moving
or rotating parts, as well as hot surfaces.
In case of inadmissible removal of the required covers, of
improper use, wrong installation or maloperation, there is the
danger of serious personal injury and damage to property.
For further information, see documentation.
All operations serving transport, installation and commissioning
as well as maintenance are to be carried out by skilled techni-
cal personnel (Observe IEC 364 or CENELEC HD 384 or DIN
VDE 0100 and IEC 664 or DIN/VDE 0110 and national accident
prevention rules!).
For the purposes of these basic safety instructions, “skilled
technical personnel” means persons who are familiar with the
installation, mounting, commissioning and operation of the
product and have the qualifications needed for the performance
of their functions.
2. Intended use
Drive converters are components designed for inclusion in elec-
trical installations or machinery.
In case of installation in machinery, commissioning of the drive
converter (i.e. the starting of normal operation) is prohibited until
the machinery has been proved to conform to the provisions of
the directive 89/39/EEC (Machinery Safety Directive - MSD).
Account is to be taken of EN 6004.
Commissioning (i.e. the starting of normal opertion) is admissible
only where conformity with the EMC directive (89/336/EEC) has
been established.
The drive converters meet the requirements of the low-voltage
directive 73/3/EEC. They are subject to the harmonized stand-
ards of the series prEN 50178/DIN VDE 0160 in conjunction with
EN 60439-1/ VDE 0660, part 500, and EN 60146/ VDE 0558.
The technical data as well as information concerning the sup-
ply conditions shall be taken from the rating plate and from the
documentation and shall be strictly observed.
3. Transport, storage
The instructions for transport, storage and proper use shall be
complied with.
The climatic conditions shall be in conformity with prEN 50178.
4. Installation
The installation and cooling of the appliances shall be in accord-
ance with the specifications in the pertinent documentation.
The drive converters shall be protected against excessive
strains. In particular, no components must be bent or isolating
distances altered in the course of transportation or handling. No
contact shall be made with electronic components and con-
tacts.
Drive converters contain electrostatic sensitive components
which are liable to damage through improper use. Electric
components must not be mechanically damaged or destroyed
(potential health risks).
5. Electrical connection
When working on live drive converters, the applicable national
accident prevention rules (e.g. VBG 4) must be complied with.
The electrical installation shall be carried out in accordance with
the relevant requirements (e.g. cross-sectional areas of conduc-
tors, fusing, PE connection). For further information, see docu-
mentation.
Instructions for the installation in accordance with EMC require-
ments, like screening, earthing, location of filters and wiring,
are contained in the drive converter documentation. They must
always be complied with, also for drive converters bearing a
CE marking. Observance of the limit values required by EMC
law is the responsibility of the manufacturer of the installation or
machine.
6. Operation
Installations which include drive converters shall be equipped
with additional control and protective devices in accordance with
the relevant applicable safety requirements, e.g. Act respecting
technical equipment, accident prevention rules etc. Changes
to the drive converters by means of the operating software are
admissible.
After disconnection of the drive converter from the voltage
supply, live appliance parts and power terminals must not be
touched immediately because of possibly energized capacitors.
In this respect, the corresponding signs and markings on the
drive converter must be respected.
During operation, all covers and doors shall be kept closed.
7. Maintenance and servicing
The manufacturer’s documentation shall be followed.
Keep safety instructions in a safe place!
Safety and operating instructions
for drive converters DCS / DCF / DCR
(in conformity with the low-voltage directive 73/23/EEC)
en
g
lis
h
Содержание DCS800
Страница 1: ...DCS800 Quick guide DCS800 Drives 20 A to 5200 A...
Страница 38: ...94 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf...
Страница 39: ...95 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf Macros Firmware...
Страница 40: ...96 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf...
Страница 41: ...97 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf Macros Firmware...
Страница 42: ...98 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf...
Страница 43: ...99 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf Macros Firmware...
Страница 44: ...100 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf...
Страница 45: ...101 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf Macros Firmware...
Страница 46: ...102 3ADW000191R0500 DCS800 Quick guide edisf e DCS8_macros dsf...
Страница 47: ...103 3ADW000191R0500 DCS800 Quick guide edisf e DCS800_Fw_structure_diagram_rev_g dsf Macros Firmware...
Страница 48: ...104 3ADW000191R0500 DCS800 Quick guide edisf e DCS800_Fw_structure_diagram_rev_g dsf...
Страница 49: ...105 3ADW000191R0500 DCS800 Quick guide edisf e DCS800_Fw_structure_diagram_rev_g dsf Macros Firmware...
Страница 50: ...106 3ADW000191R0500 DCS800 Quick guide edisf e...
Страница 51: ...107 3ADW000191R0500 DCS800 Quick guide edisf e 3ADW 000 208 R0101...