1.3 Improper
use
The following uses of the device are prohibited:
•
Operation as a flexible adapter in piping, e. g., to compensate for pipe offsets, pipe
vibrations, pipe expansions, etc.
•
Use as a climbing aid, e. g., for assembly purposes.
•
Use as a support for external loads, e.g., as a support for pipes, etc.
•
Material gain, e. g., by painting over the name plate or adding parts by welding / soldering.
•
Material loss, e. g., by drilling the housing.
Pos: 5.8 /Sicherheit/Allgemein/Hinweis zur bestimmungswidrigren Verwendung (Wartung/Reparatur) @ 0\mod_1129707002440_3101.doc @ 3240 @
Repairs, alterations, and enhancements, or the installation of replacement parts, are only
permissible insofar as these are described in the manual. Approval by ABB Automation
Products GmbH must be sought for any activities beyond this scope. Repairs performed by
ABB-authorized specialist shops are excluded from this.
Pos: 5.9 /Sicherheit/Durchfluss/FCM2000/Technische Grenzwerte FCM2000 (Durchfluss) @ 8\mod_1178192769312_3101.doc @ 88354 @
1.4 Technical
limit
values
The device is designed for use exclusively within the stated values on the name plate and within
the technical limit values specified in the data sheets.
The following technical limit values must be observed:
• The permissible pressure (PS) in the permissible temperature (TS) may not exceed the
pressure-temperature ratings (see "Technical data").
• The maximum or minimum operating temperature limits may not be exceeded.
• The permitted operating temperature may not be exceeded.
• The housing protection system must be observed.
• The flowmeter primary may not be operated in the vicinity of powerful electromagnetic fields,
e.g., motors, pumps, transformers, etc. A minimum spacing of approx. 1 m (3,28 ft.) should
be maintained. For installation on or to steel parts (e.g., steel brackets), a minimum spacing
of approx. 100 mm (4“) should be maintained (based on IEC801-2 and IECTC77B).
Pos: 5.10 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830 @
Содержание CoriolisMaster FCM2000
Страница 112: ...Appendix 112 CoriolisMaster FCM2000 D184B111U02...
Страница 113: ...Appendix D184B111U02 CoriolisMaster FCM2000 113...
Страница 114: ...Appendix 114 CoriolisMaster FCM2000 D184B111U02...
Страница 115: ...Appendix D184B111U02 CoriolisMaster FCM2000 115...
Страница 116: ...Appendix 116 CoriolisMaster FCM2000 D184B111U02...
Страница 117: ...Appendix D184B111U02 CoriolisMaster FCM2000 117...
Страница 118: ...Appendix 118 CoriolisMaster FCM2000 D184B111U02...
Страница 119: ...Appendix D184B111U02 CoriolisMaster FCM2000 119...
Страница 120: ...Appendix 120 CoriolisMaster FCM2000 D184B111U02...
Страница 123: ...Appendix D184B111U02 CoriolisMaster FCM2000 123 Pos 56 12 Seitenumbruch 0 mod_1126532365768_3101 doc 3830...