![ABB CMS-700 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/abb/cms-700/cms-700_user-manual_2669062.webp)
CMS-700 SYSTEM
CIRCUIT MONITORING SYSTEM (CMS)
61
Addr.
(hex)
Addr.
(dec)
Word
(16-bit)
Description
Resolution
(1-bit value)
Unit
Format
Access
SNMP
Variable Name
Branches
3200
12'800
64
Branch name of Sensor 1
64
letter
string
RW (03,10) BranchNameSens1
3240
12'864
64
Branch name of Sensor 2
64
letter
string
RW (03,10) BranchNameSens2
…
…
64
…
64
letter
string
RW (03,10)
…
49C0
18'880
64
Branch name of Sensor 96
64
letter
string
RW (03,10) BranchNameSens96
5200
20'992
64
Name of Group 1*
64
letter
string
RW (03,10) GroupName1
5240
21'056
64
Name of Group 2
64
letter
string
RW (03,10) GroupName2
…
…
64
…
64
letter
string
RW (03,10)
…
69C0
27'072
64
Name of Group 96
64
letter
string
RW (03,10) GroupName96
7200
29'184
1
Phase assigned to Sensor 1
1
short
RW (03,06) PhaseSens1
7201
29'185
1
Phase assigned to Sensor 2
1
short
RW (03,06) PhaseSens2
…
…
1
…
1
short
RW (03,06)
…
725F
29'279
1
Phase assigned to Sensor 96
1
short
RW (03,06) PhaseSens96
7280
29'312
1
Group number of Sensor 1**
1
short
RW (03,06) GroupSens1**
7281
29'313
1
Group number of Sensor 2
1
short
RW (03,06) GroupSens2
…
…
1
…
1
short
RW (03,06)
…
72DF
29'407
1
Group number of Sensor 96
1
short
RW (03,06) GroupSensor96
7300
29'440
1
Power Factor of Sensor 1
0.01
unsigned
RW (03,06) PowerFactorSens1
7301
29'441
1
Power Factor of Sensor 2
0.01
unsigned
RW (03,06) PowerFactorSens2
…
…
1
…
0.01
unsigned
RW (03,06)
…
735F
29'553
1
Power Factor of Sensor 96
0.01
unsigned
RW (03,06) PowerFactorSens96
Alarm/Event Status – only Status
8000
32'768
1
Number of current alarms
unsigned
R (03)
8001
32'769
1
Alarm Status Branch 1
unsigned
R (03)
8002
32'770
1
Alarm Status Branch 2
unsigned
R (03)
...
...
1
unsigned
R (03)
8060
32'864
1
Alarm Status Branch 96
unsigned
R (03)
8061
32'865
1
Alarm Status Line L1
unsigned
R (03)
8062
32'866
1
Alarm Status Line L2
unsigned
R (03)
8063
32'867
1
Alarm Status Line L3
unsigned
R (03)
8064
32'868
1
Alarm Status Line L4/N
unsigned
R (03)
Alarm/Event Status – Status and Threshold
8100
33'024
1
Number of current alarms
unsigned
R (03)
8101
33'025
1
Alarm Status Branch 1
unsigned
R (03)
8102
33'026
2
Alarm Threshold Branch 1
signed
R (03)
8104
33'028
1
Alarm Status Branch 2
unsigned
R (03)
8105
33'029
2
Alarm Threshold Branch 2
signed
R (03)
...
...
R (03)
821E
33'310
1
AlarmStatusBranch96
unsigned
R (03)
821F
33'311
2
AlarmThresholdBranch96
signed
R (03)
...
...
8221
33'313
1
AlarmStatusLine L1
unsigned
R (03)
8222
33'314
2
AlarmThresholdLine L1
signed
R (03)
8224
33'316
1
AlarmStatusLine L2
unsigned
R (03)
8225
33'317
2
AlarmThresholdLine L2
signed
R (03)
8227
33'319
1
AlarmStatusLine L3
unsigned
R (03)
8228
33'320
2
AlarmThresholdLine L3
signed
R (03)
822A
33'322
1
AlarmStatusLine L4/N
unsigned
R (03)
822B
33'323
2
AlarmThresholdLine L4/N
signed
R (03)
—