Electrical installation
58
Connecting the control cables
Control connections to the JCU Control Unit
Notes:
[Default setting]
*Total maximum current: 200 mA
**Default assignment with ACSM1
Motion Control Program
The wiring shown is for demonstrative
purposes only. Further information of
the usage of the connectors and
jumpers are given in the text; see also
the chapter
.
Wire sizes and tightening torques:
X2: 0.5 … 2.5 mm
2
(24…12 AWG).
Torque: 0.5 N·m (5 lbf·in)
X3, X4, X5, X6:
0.5 … 1.5 mm
2
(28…14 AWG).
Torque: 0.3 N·m (3 lbf·in)
X1
External power input
24 V DC, 1.6 A
+24VI
1
GND
2
X2
Relay output
250 V AC / 30 V DC
2 A
NO
1
COM
2
NC
3
X3
+24 V DC*
+24VD
1
Digital I/O ground
DGND
2
Digital input 1 [Stop/Start]
DI1
3
Digital input 2 [EXT1/EXT2]
DI2
4
+24 V DC*
+24VD
5
Digital I/O ground
DGND
6
Digital input 3 [Fault reset]
DI3
7
Digital input 4 [Positioning start]**
DI4
8
+24 V DC*
+24VD
9
Digital I/O ground
DGND
10
Digital input 5 [Position ref. set 1/2]**
DI5
11
Digital input 6 [Homing start]**
DI6
12
+24 V DC*
+24VD
13
Digital I/O ground
DGND
14
Digital input/output 1 [Ready]
DIO1
15
Digital input/output 2 [Running]
DIO2
16
+24 V DC*
+24VD
17
Digital I/O ground
DGND
18
Digital input/output 3 [Fault]
DIO3
19
X4
Reference voltage (+)
+VREF
1
Reference voltage (–)
-VREF
2
Ground
AGND
3
Analogue input 1 (Current or voltage, selectable
by jumper J1) [Speed reference]
AI1+
4
AI1-
5
Analogue input 2 (Current or voltage, selectable
by jumper J2) [Torque reference]
AI2+
6
AI2-
7
AI1 current/voltage selection
J1
AI2 current/voltage selection
J2
Thermistor input
TH
8
Ground
AGND
9
Analogue output 1 (current) [Output current]
AO1 (I)
10
Analogue output 2 (voltage) [Actual speed]
AO2 (U)
11
Ground
AGND
12
X5
Drive-to-drive link termination
J3
Drive-to-drive link.
B
1
A
2
BGND
3
X6
Safe Torque Off. Both circuits must be closed for
the drive to start.
OUT1
1
OUT2
2
IN1
3
IN2
4
Control panel connection
X7
Memory unit connection
X205
X3 (4 × 4-pole,
1 × 3-pole)
X2 (3-pole)
X1 (2-pole)
X4 (1 × 7-pole,
1 × 2-pole,
1 × 3-pole)
X5 (3-pole)
X6 (4-pole,
orange)
J1
J3
J2
Order of terminal headers and
jumpers
T
Содержание ACSM1-04 Series
Страница 1: ...ACSM1 Hardware Manual ACSM1 04 Drive Modules 55 to 110 kW ...
Страница 2: ......
Страница 4: ......
Страница 18: ...About this manual 18 ...
Страница 22: ...The ACSM1 04 22 ...
Страница 64: ...Electrical installation 64 ...
Страница 70: ...Maintenance 70 ...
Страница 82: ...Technical data 82 ...
Страница 88: ...Dimension drawings 88 Drive module ...
Страница 89: ...Dimension drawings 89 Drive module continued from previous page ...
Страница 91: ......