Inlet manifold with stop and drain valves
-
13
Outlet manifold with stop and drain valves
-
14
Heat exchanger
-
15
Converter module hardware
■
Module layout
2a
2b
6
3b
5
3a
4
10
9
7
1a
8
1b
DC connection busbars, + (a) and - (b)
1
Lifting eyes, front (a) and back (b)
2
Coolant in (a) and out (b) connectors
3
Handle
4
Fiber optic connectors
5
Quick connector (AC connection) (the counterpart fastened to the cabinet behind the module)
6
Terminal block X50 (auxiliary power input for internal boards)
7
Terminal block X51 and X52 (Safe torque off in inverter modules only)
8
Terminal block X53 (24 V DC power output)
9
Auxiliary voltage selector (115 or 230 V)
10
Unpainted fastening hole. The grounding point (PE) between module frame and cabinet frame.
11
20 Operation principle and hardware description