-40 … +70 °C
-40 … +70 °C
0 … +45 °C
(+32 … +113 °F), no con-
densation allowed. Output
derated in the range
+45 … +55 °C
(+113 … +131 °F).
Air temperature
(-40 … +158 °F)
(-40 … +158 °F)
Maximum 95%, no con-
densation allowed
Maximum 95%, no con-
densation allowed
Maximum 95%, no con-
densation allowed
Relative humidity
No condensation allowed. Maximum allowed relative humidity is 60% in the presence
of corrosive gases.
IEC 60721-3-2
IEC 60721-3-1
IEC/EN 60721-3-3:2002:
Classification of environ-
mental conditions - Part 3-
3: Classification of groups
of environmental paramet-
ers and their severities -
Stationary use of weather
protected locations
Contamination
Class 2C2
Class 1C2
Class 3C2
Chemical gases
Class 2S2
Class 1S3 (packing must
support this, otherwise
1S2)
Class 3S1
Solid particles
No conductive dust al-
lowed.
IEC/EN 60721-3-1:1997
IEC/EN 60721-3-1:1997
IEC 61800-5-1
Vibration
IEC 60068-2-6:2007,
EN 60068-2-6:2008 Envir-
onmental testing Part 2:
Tests -Test Fc: Vibration
(sinusoidal)
10 … 57 Hz, max.
0.075 mm amplitude
57 … 150 Hz 1
g
Tested in a typical cabinet
assembly according to:
Max. 1 mm (0.04 in.)
(peak value, 5 … 13.2 Hz),
max. 0.7
g
(13.2 … 100 Hz) sinusoidal
With packing max.
100 m/s
2
(330 ft./s
2
) 11 ms
With packing max.
100 m/s
2
(330 ft./s
2
) 11 ms
Not allowed
Shock
IEC 60068-2-27:2008,
EN 60068-2-27:2009
Environmental testing -
Part 2-27: Tests - Test Ea
and guidance: Shock
98 Technical data
Содержание ACS880-1607LC
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 1607LC DC DC converter units Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 12: ...12 ...
Страница 32: ...32 ...
Страница 38: ...38 ...
Страница 60: ...60 ...
Страница 80: ...80 ...
Страница 90: ...90 ...
Страница 102: ...Unit with 1 R8i converter module 102 Dimension drawings ...
Страница 103: ...Dimension drawings 103 ...
Страница 104: ...Location and size of energy storage connection terminals 104 Dimension drawings ...