Description
Example value
Name
Index
Sets the negative speed limit that trips the
drive for the SMS function.
-2000 rpm
SMS trip limit negat-
ive
SMS.13
Note:
You cannot set this limit above the
general zero speed limit (parameter FSO-
GEN.52).
Note:
The default value after factory reset
is
0
rpm.
Always check this parameter after factory
reset.
Sets the positive speed limit that trips the
drive for the SMS function.
2000 rpm
SMS trip limit posit-
ive
SMS.14
Note:
You cannot set this limit below the
general zero speed limit (parameter FSO-
GEN.52).
Note:
The default value after factory reset
is
0
rpm.
Always check this parameter after factory
reset.
Parameters for the SSM function
There are four separate SSM functions (SSM1...4) in the FSO module. The SSM functions
are identical and the configuration is done similarly, only the parameter numbers differ. The
SSM1 function is shown as an example. ABB has activated the SSM1 function at the factory.
For more information, see FSO-21 module user’s manual.
Description
Example value
Name
Index
Activates or deactivates the SSM1 function
and shows the version of the SSM1 func-
tion.
Version 1
SSM1 activity and
version
SSMx.01
Disabled
: Deactivates the SSM1 function.
Version 1
: Activates the SSM1 function.
For the Q965, ABB has activated
the SSM1 function at the factory. Adjust the
value if necessary.
Sets the digital input connected to the
SSM1 function.
Always on
SSM1 input
SSMx.11
Always on
: The SSM1 function is always
on. No external request signal is needed to
activate the SSM1 function.
For the Q965, ABB has configured
the SSM1 function to be “Always on” at the
factory.
Sets the negative speed limit for the SSM1
function.
-100 rpm
SSM1 limit negative
SSMx.12
Sets the positive speed limit for the SSM1
function.
100 rpm
SSM1 limit positive
SSMx.13
Option description 43