52 Parameters
Parameters in the Long parameter mode
The following table includes the complete descriptions of all parameters that are
visible only in the Long parameter mode.
Parameters in the Long parameter mode
Index
Name/Selection
Description
Def
0000 Read only parameters access
Press the
button when in this parameter to access
the read only parameters as listed on page 46.
.
-
04
FAULT HISTORY
Fault history (read-only)
0401
TRIP HISTORY LOG
Displays the last four fault codes for the drive.
Press UP or DOWN to step through all four. The most
recent trip is always displayed first. The Under Voltage
(F0006) trip is only stored once.
-
11
REFERENCE SELECT
The drive can accept a variety of references in addition to
the conventional analog input, potentiometer and keypad
signals.
1100
KEYPAD MODE RESTART
FUNCTION
This parameter is active only when operating in Keypad
Control Mode (parameter
1103
PRIMARY COMMAND
SOURCE MODE = 1 or 2).
0
0
MINIMUM SPEED,
KEYPAD START
Keypad Start and Stop keys are active, and control
terminals 1 and 2 must be linked together. The drive will
always start at the Minimum Frequency / Speed
(parameter
2007
)
1 : PREVIOUS SPEED,
KEYPAD START
Keypad Start and Stop keys are active, and control
terminals 1 and 2 must be linked together.
The drive will always start at the last operating Frequency
/ Speed
2 : MINIMUM SPEED,
TERMINAL ENABLE
Allows the drive to be started from the control terminals
directly, and the keypad Start and Stop keys are ignored.
The drive will always start at the Minimum Frequency /
Speed (parameter
2007
)
3 : PREVIOUS SPEED,
TERMINAL ENABLE
Allows the drive to be started from the control terminals
directly, and the keypad Start and Stop keys are ignored.
The drive will always start at the last operating Frequency
/ Speed.
4 : CURRENT SPEED ,
KEYPAD START
5 : PRESET SPEED 4 ,
KEYPAD START
6 : CURRENT SPEED ,
TERMINAL START
7 : PRESET SPEED 4 ,
TERMINAL START
1103
PRIMARY COMMAND
SOURCE MODE
0
0: TERMINAL CONTROL.
The drive responds directly to signals applied to the
control terminals.
1: UNI-DIRECTIONAL
KEYPAD CONTROL
The drive can be controlled in the forward direction only
using an external or remote Keypad
ACS260-04.book Page 52 Thursday, December 24, 2020 4:33 PM
Содержание ACS260-04 Series
Страница 2: ...ACS260 04 book Page 2 Thursday December 24 2020 4 33 PM ...
Страница 4: ...ACS260 04 book Page 4 Thursday December 24 2020 4 33 PM ...
Страница 8: ...8 Table of contents ACS260 04 book Page 8 Thursday December 24 2020 4 33 PM ...
Страница 14: ...14 Safety ACS260 04 book Page 14 Thursday December 24 2020 4 33 PM ...
Страница 22: ...22 Mechanical installation ACS260 04 book Page 22 Thursday December 24 2020 4 33 PM ...
Страница 32: ...32 Electrical installation ACS260 04 book Page 32 Thursday December 24 2020 4 33 PM ...
Страница 92: ...92 Technical Data ACS260 04 book Page 92 Thursday December 24 2020 4 33 PM ...
Страница 96: ...96 Options and Kits ACS260 04 book Page 96 Thursday December 24 2020 4 33 PM ...