Parameters 49
Parameters in the Short parameter mode
The following table describes the parameters that are visible in the Short parameter
mode.
Parameters in the Short parameter mode
No.
Name/Value
Description
Def
99 START-UP DATA
Application macros.
9902
DIGITAL INPUTS
FUNCTION SELECT
Defines the function of the digital inputs
depending on the control mode setting in
Parameter
1103
PRIMARY COMMAND
SOURCE MODE.
0
9905
MOTOR RATED
VOLTAGE
This parameter should be set to the rated
(nameplate) voltage of the motor (Volts).
Drive Rating
Dependent
0…500V
Voltage
Note :
The stress on the motor insulation is
always dependent on the drive supply voltage.
This also applies in the case where the motor
voltage rating is lower than the rating of the drive
and the supply of the drive.
9906
MOTOR RATED
CURRENT
This parameter should be set to the rated
(nameplate) current of the motor.
Drive Rating
Dependent
0.25*drive rated output
current…1.0*drive rated
output current
Current
9907
MOTOR RATED
FREQUENCY
This parameter should be set to the rated
(nameplate) frequency of the motor
50HZ
25…500Hz
Frequency
04 FAULT HISTORY
Fault history (read only)
0401
TRIP HISTORY LOG
Displays the last four fault codes for the drive.
-
11 REFERENCE SELECT
The drive can accept a variety of references in
addition to the conventional analog input,
potentiometer and keypad signals.
1103
PRIMARY COMMAND
SOURCE MODE
0: Terminal
Control
0: TERMINAL CONTROL.
The drive responds directly to signals applied to
the control terminals.
1: UNI-DIRECTIONAL
KEYPAD CONTROL
The drive can be controlled in the forward
direction only using an external or remote
Keypad
2: BI-DIRECTIONAL
KEYPAD CONTROL.
The drive can be controlled in the forward and
reverse directions using an external or remote
Keypad. Pressing the keypad START button
toggles between forward and reverse.
3: MODBUS NETWORK
CONTROL.
Control via Modbus RTU (RS485) using the
internal accel / decel ramps
4 : MODBUS NETWORK
CONTROL.
Control via Modbus RTU (RS485) interface with
accel / decel ramps updated via Modbus
5 : PI CONTROL
User PI control with external feedback signal
6 : PI ANALOG
SUMMATION CONTROL.
PI control with external feedback signal and
summation with analog input 1
ACS260-04.book Page 49 Thursday, December 24, 2020 4:33 PM
Содержание ACS260-04 Series
Страница 2: ...ACS260 04 book Page 2 Thursday December 24 2020 4 33 PM ...
Страница 4: ...ACS260 04 book Page 4 Thursday December 24 2020 4 33 PM ...
Страница 8: ...8 Table of contents ACS260 04 book Page 8 Thursday December 24 2020 4 33 PM ...
Страница 14: ...14 Safety ACS260 04 book Page 14 Thursday December 24 2020 4 33 PM ...
Страница 22: ...22 Mechanical installation ACS260 04 book Page 22 Thursday December 24 2020 4 33 PM ...
Страница 32: ...32 Electrical installation ACS260 04 book Page 32 Thursday December 24 2020 4 33 PM ...
Страница 92: ...92 Technical Data ACS260 04 book Page 92 Thursday December 24 2020 4 33 PM ...
Страница 96: ...96 Options and Kits ACS260 04 book Page 96 Thursday December 24 2020 4 33 PM ...