![ABB ACS 300 Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/abb/acs-300/acs-300_user-manual_3269097.webp)
ACS 300 User’s Manual
83
Chapter 9 - Technical Data
Mains Connection
Motor Connection
1)
Check type-specific, refer to Table 1-1 and Table 1-2.
Voltage
1 and 3 phase
208 to 240 V
±
10 %
1 and 3 phase
200 to 240 V
-7%
+10%
3 phase
380 to 480 V
±
10 %
Frequency
48 to 63 Hz
Fundamental power factor
approximately 0.98
Voltage
3 phase, 0 - U
MAINS
Frequency
0 to 500 Hz
Switching frequency f
s
1.0 to 16.0 kHz
Continuous load capacity,
constant torque at a maximum
ambient temperature of 50
°
C
ACS 300 rated
current
see Figure 2-1
Overload capacity at a maximum
ambient temperature of
50
°
C
Constant torque
1.5 * I
N
1 min every 10 min,
if switching frequency < 8 kHz
1)
Starting duty
1.5 * I
N
1 min every 10 min,
if switching frequency < 8 kHz
1)
Nominal motor voltage
200 to 240 V
360 to 500 V
Acceleration time
0.1 to 1800 s
see page 48
Deceleration time
0.1 to 1800 s
see Chapter 7 - Drive Parame-
ters
Содержание ACS 300
Страница 14: ...xiv ACS 300 User s Manual Table of Contents ...
Страница 24: ...10 ACS 300 User s Manual Chapter 1 Overview of This Manual ...
Страница 28: ...14 ACS 300 User s Manual Chapter 2 Mechanical Installation ...
Страница 33: ...ACS 300 User s Manual 19 Chapter 3 Power Connections Figure 3 5 Cable connections for frame size R2 ...
Страница 50: ...36 ACS 300 User s Manual Chapter 4 Control Connections ...
Страница 60: ...46 ACS 300 User s Manual Chapter 6 Control and Parameter Logic ...