ACS 300 User’s Manual
33
Chapter 4 - Control Connections
Table 4-11 Constant speed selection.
Alternate 2
Switch S1 is in the same position as in Alternate selection.
Parameter PARAM SET has value 2.
Table 4-12 Alternate 2 digital input functions.
Table 4-13 Constant speed and parameter set selection.
DI3
DI4
Result
0
0
Speed reference from AI1
+24 V
0
Constant speed 1
0
+24 V
Constant speed 2
+24 V
+24 V
Constant speed 3
Digital input
Function
Notes
DI1
Start forward
C24 V DC to Start/Reverse,
refer to Table 4-10
DI2
Start reverse
DI3
CS1
Constant speed (=CS) selection,
refer to Table 4-13
DI4
CS2
DI5
Parameter set selection
0 V= set 1 and +24 V= set 2
DI3
DI4
DI5
Result
0
0
0
Speed reference from AI1
1
0
0
CS1 (parameter Page 2)
0
1
0
CS2 (parameter Page 2)
1
1
0
CS3 (parameter Page 2)
0
0
1
Speed reference from AI1
1
0
1
CS1 (parameter Page 4)
0
1
1
CS2 (parameter Page 4)
1
1
1
CS3 (parameter Page 4)
Содержание ACS 300