06 MECHANICAL INSTALLATION
3BHS213401 E01 REV H
ACS1000 AIR-COOLED
USER MANUAL
81/184
6. Before you lower the redundant fan unit onto the cabinet roof, check that the gasket
between cabinet roof and redundant fan unit is properly placed.
7. Fasten the redundant fan unit on both sides to the cabinet roof.
8. Attach the sound absorbing panels to the right side of the redundant fan unit.
Note:
Recommended sequence: 1, 2, 3.
9. After the power supply cable of the redundant fan unit and the transformer and motor
cables have been entered into the cabinet, attach the sound absorbing panels to the left
side of the redundant fan unit.
10. Continue with the electrical installation of the power supply cable.
See “7.7 Power supply cable for redundant fan unit” on page 104.
1
2
3
Содержание ACS 1013-A1
Страница 1: ... MEDIUM VOLTAGE AC DRIVES ACS1000 air cooled User manual ...
Страница 3: ...Contents ACS1000 air cooled User manual ...
Страница 5: ... 01 About this manual 01 3 14 ...
Страница 16: ......
Страница 17: ... 02 Important safety information 02 15 26 ...
Страница 28: ......
Страница 29: ... 03 Power electronics and cabinet features03 27 50 ...
Страница 53: ... 04 Control system 04 51 66 ...
Страница 68: ......
Страница 69: ... 05 Transportation storage and disposal05 67 74 ...
Страница 76: ......
Страница 77: ... 06 Mechanical installation 06 75 82 ...
Страница 84: ......
Страница 85: ... 07 Electrical installation07 83 106 ...
Страница 108: ......
Страница 109: ... 08 Commissioning 08 107 112 ...
Страница 115: ... 09 Operation 09 113 126 ...
Страница 129: ... 10 CDP control panel 10 127 150 ...
Страница 153: ... 11 Preventive and corrective maintenance 11 151 182 ...
Страница 185: ......