Operation Manual / A170-M.. - A175-M..
8 Troubleshooting / 8.1 Malfunctions when starting
© Copyright 2021 ABB. All rights reserved.
HZTL4033_EN
Rev.H
July 2021
8
Troubleshooting
8.1
Malfunctions when starting
Delayed start-up
Possible causes
Remedy
Turbochar-
ger
Turbocharger contaminated
Bearing damaged
Contact ABB Turbocharging Service
Station
Rotor rubbing
Foreign object in the turbocharger
Table 20: Malfunctions when starting – Delayed start-up
Vibrations
Possible causes
Remedy
Turbochar-
ger
Rotor unbalance
Contact ABB Turbocharging Service
Station
Turbine or compressor damaged
Bearing damaged
Engine
Vibrations from engine
Contact enginebuilder
Table 21: Malfunctions when starting – Vibrations
Rubbing of rotating parts
Normal behaviour, not a malfunction
Turbochar-
ger
A slight amount of uniform wear at the circumference of the rotor components
caused by slight local rubbing against adjacent components is permitted. This
causes the compressor or turbine blades to be somewhat shortened. To prevent
significant loss of efficiency, specific tolerances must be fulfilled.
¡
If there is any doubt about the extent of the rubbing, contact an ABB Tur-
bocharging Service Station.
¡
Have a dimension check carried out by an ABB Turbocharging Service Sta-
tion.
Table 22: Malfunctions when starting – Rubbing of rotating parts
Page
70
/
147
Содержание A175-M66
Страница 2: ......
Страница 145: ...Operation Manual A170 M A175 M 14 Tools Copyright 2021 ABB All rights reserved HZTL4033_EN Rev H July 2021 Page 143 147 ...
Страница 150: ......