38
2 6 6 H S H MODBUS TR A N S M IT TE R |
P R E SSU R E/ T EM P ER AT U R E M U LT I VA R I A B L E | O I/ 2 6 6 H SH M T- EN R E V. A
— Configuration related error messages.
Error
message
Tx LCD message Possible cause
Suggested action
Tx response
C088.030
Input Simulation
Active
The P-dP Value produced in output is
derived by the value simulated in input.
Use a HART configurator (DTM - Hand held) to
place device back in to normal operating mode
(Remove the input simulation).
no effect
C088.030
Input Simulation
Active
The Static Pressure Value produced in
output is derived by the value
simulated in input.
Use a HART configurator (DTM - Hand held) to
place device back in to normal operating mode
(Remove the input simulation).
no effect
C088.030
Input Simulation
Active
The Sensor Temperature Value
produced in output is derived by the
value simulated in input.
Use a HART configurator (DTM - Hand held) to
place device back in to normal operating mode
(Remove the input simulation).
no effect
M014.037
Configuration
Error
Refer to the Instruction manual to
understand the possible cause of this
error.
Use a HART configurator (DTM - Hand held) to
correct the configuration.
no effect
M020.042
Replace Info
The Electronics or the Sensor have
been changed but the replacement
operation has not been executed.
The replacement operation must be executed:
Move the SW 1 of the electronics in position 1 =
Enable replace mode -Select the SW 2 the element
that has been changed between new Sensor or
new electronics -Power Cycle the device -Move the
SW 1 of the electronics in position 0.
no effect
M020.042
Replace Info
The Electronics or the Sensor have
been changed and a replacement
operation for a new sensor has to be
executed.
The replacement operation must be executed:
Only the data of the electronics can be copied into
the sensor-Move the SW 1 to Enable replace mode
(1)-Select with the SW 2 to New Sensor (1)-Power
Cycle the device-Move the SW 1 to Disable replace
mode (0).
no effect
M020.042
Replace Info
The Electronics or the Sensor have
been changed.
The replacement has been enabled but
with a wrong direction (SW 2 = 0).
Change the replacement direction (if possible)-
The SW 1 is already set to Enable replace mode
(1)-Select with the SW 2 to New Sensor (1)-Power
Cycle the device-Move the SW 1 to Disable replace
mode (0).
no effect