7.16 Standard HART software revision history
Revision
Description
Release date
From
To
7.1.50
First release
02/2013
7.1.51
Internal release not published
7.1.52
Internal release not published
7.1.52
7.1.53
Bug Fixing:
— HART burst mode
— correcting Custom unit visualization on LCD
Improvements:
— boot loader performance
— HART secondary response code
— Electronics temperature reading
01/2014
7.1.53
7.1.54
Integrated LCD firmware integration
07/2014
7.1.54
7.1.55
Bug fixing on EEPROM
10/2014
7.1.55
7.1.56
Obsolete Microprocessor replacement
06/2016
7.1.56
7.2.50
HART 7 Introduction
10/2016
7.1.56
7.1.74
(HART 5)
Several bug fixing
10/2018
7.2.50
7.2.54
(HART 7)
Several bug fixing and certification
HART burst mode removed
Intermediate releases for internal tests not published
8 Error messages
8.1 LCD Display messages
The LCD HMI in case of transmitter errors or malfunctioning is capable of displaying specific error/fault
messages to help the user in identifying the problem and resolve it. In case of an alarm, a message consisting
of an icon and text appears at the bottom of the process display, as shown hereafter. Use the (1) key to call up
the information level. Use the “Diagnostics” menu to call up the error description with a help text. In the error
description, the error number is displayed in the second line (M028.018). Two further lines are used to describe
the error. The device status is divided into four groups. The message text beside this icon in the display
provides information about where to look for the error. There are the following areas: Electronic, Sensor,
Configuration, Operanting and Process.
Icon
Description
Error / Failure
Functional check (e.g. during simulation )
Out of Spec (e.g. operating with empty meter pipe)
Maintenance required