Communication
6 – 2
Advant Controller AC 31 / Issued: 01.99
3
Note:
The default setting is
-
Digital area with:
-
transmit 4 bytes and
-
receive 4 bytes.
This is defined by the default combination
KW 00,10 = KW 00,11 = 0.
The configured combination
KW 00,10 = KW 00,11 = 4
has the same result as the default combination.
The combination:
KW 00,10 = KW 00,11 = 100.
Is not allowed (It would mean transmit 0 words and receive 0 words)
If used in the word area, the top 8 channels of the address which are not used may be
occupied by an analog unit, if required.
Õ
Changing the system constants takes effect immediately.
•
Size of the receiving area of the slave basic unit
Õ
Absolute identifier:
KW 00,11
Õ
Symbolic identifier:
SLV_REC
Õ
Meaning of the value of the constants :
The slave basic unit can be used at the CS31 system bus in
either the digital area or the
word area. It is possible to set the number of bytes or words which are to be sent from the
master basic unit to the slave basic unit.
-
For use in the digital area:
Transmitting: 2...15 bytes
2...15
-
For use in the word area:
Transmitting: 1...8 words
101...108
Õ
Default value:
4
-
Range of values:
2...15 and 101...108
Changes to these system constants take effect:
Õ
on the next warm start or
Õ
on the next cold start
Note:
The default setting is
-
Digital area with:
-
transmit 4 bytes and
-
receive 4 bytes.
This is defined by the default combination
KW 00,10 = KW 00,11 = 0.
The configured combination
KW 00,10 = KW 00,11 = 4
has the same result as the default combination.
The combination:
KW 00,10 = KW 00,11 = 100.
Is not allowed (It would mean transmit 0 words and receive 0 words)
Õ
If used in the word area, the top 8 channels of the address which are not used may be
occupied by an analog unit, if required.
Õ
Changing the system constants takes effect immediately.
Содержание 07AC91
Страница 6: ...Contents 4 Advant Controller AC 31 Issued 08 99 3 ...
Страница 58: ...Installation 4 10 Advant Controller AC 31 Issued 08 99 3 Figure 16 Relay outputs Figure 17 Transistor outputs ...
Страница 62: ...Installation 4 14 Advant Controller AC 31 Issued 08 99 3 Figure 22 Extension XK 08 F1 l ...
Страница 94: ...Programming 5 22 Advant Controller AC 31 Issued 01 99 3 ...
Страница 110: ...Communication 6 16 Advant Controller AC 31 Issued 01 99 3 ...
Страница 122: ...Appendix A 4 Advant Controller AC 31 Issued 08 99 3 ...
Страница 123: ......