P. 68 - Chap. 10 Maintenance
10
Maintenance
G
B
Perform the
scheduled maintenance operations to maintain compressor performance
.
Various routine maintenance operation can be carried out by user provided they are carried out by
skilled personnel.
If routine maintenance is provided by a Service Centre, the user cannot RESET the components even
if these have been replaced by the user (see paragraph 7.4.2.2)
Use only original spare parts
Instructions are provided in the following paragraphs.
Before performing any maintenance operations read the operator safety precautions in
chapter 5 carefully. These precautions must be followed scrupulously for all maintenance
operations
Operating cycle
10.1
The compressor unit consists of two rotors (male and female) with special asymmetrical profile, patented VT
series, mounted on rolling bearings, able to withstand axial and radial thrust. The male rotor is the driving rotor
while the female rotor is driven. The male rotor also rotates the female rotor. The two rotors are not however
in contact physically as they are separated by a thin film of oil that protects the coupled surfaces. The male
rotor drives and the female rotor is driven. The two rotors are not in direct contact thanks to a thin film of oil
which protects the coupled surfaces.
The oil serves various purposes. It lubricates the bearings and the rotors, eliminates the heat produced by
the compressed air, it creates an “airtight fluid seal” and reduces hazardous gaps in the air-end unit.
In fixed speed compressors, starting is of the delta-star type. During the star phase, intake valve
VA
is closed,
thus permitting no-load start-up with less effort and lower energy consumption.
After a preset time of a few seconds, the PC control unit invokes changeover to the delta connection; with a
short transient phase, the
MP
motor reaches rated rotation speed. The intake valve opens thus starting the
normal work cycle.
In variable speed compressors, the start-up phase takes place with acceleration of the electrical motor which,
powered by the inverter, is brought to maximum speed of rotation compatible with network pressure.
As soon as this is permitted by rotation speed, the intake valve
VA
opens and the machine work cycle
begins.
The air is drawn through the filter
FA
, passes into the air-end unit where it is mixed with the oil injected. The air is
gradually compressed and pushed into the separator receiver where initial oil separation occurs by gravity.
The air, which is still mixed with oil droplets, follows the shape of the receiver and passes through the oil
separator filter
FD
. Due to the effect of coalescence, the droplets of oil merge and are deposited on the bottom
of the filter from where they are routed towards the air-end unit by means of a pipe.
The purified air passes through the check and minimum pressure valve
VR
which opens only when a threshold
of approximately 4 bar is exceeded. This ensures correct system lubrication in all operating conditions.
The oil deposited on the bottom of receiver
SS
is conveyed under pressure to the oil radiator
RO
where it
is cooled. If the temperature of the oil is below the calibration value of the
VT
thermostatic valve, flow to the
Содержание GENESIS Series
Страница 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Страница 2: ......
Страница 11: ...IX FORMULA 15 kW BA 69 Fig 17 Fig 18 PC PE SPA CF FA PF CT TRL VR BF PS ES EV FU MA RA RO MP PP VA FO FO VS SS...
Страница 12: ...X MODULO 5 5 7 5 kW Fig 19 Fig 20 FO FD FA SS ES FU MA RA RO PP MP PC PE SCE SF VA EV BF VT TRL CT PF VS PS...
Страница 14: ...XII MODULO 15 kW BA 69 Fig 23 Fig 24 PS PP PF MA FU RA RO ES VA FO FD VS SS MP CF FA SCE PE PC TRL VR BF CT EV...
Страница 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Страница 84: ...P 82 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines without air dryer 12 2...
Страница 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Страница 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Страница 87: ...P 85 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 5 5 15 kW Machines without air dryer 12 5...
Страница 88: ...P 86 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 5 5 15 kW Machines with air dryer 12 6...
Страница 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...
Страница 90: ...P 88 Chap 12 Diagrams G B Wiring diagram for component location 5 5 15 kW Machines without air dryer 12 8...
Страница 91: ...P 89 Chap 12 Diagrams G B Wiring diagram for component location 5 5 15 kW Machines with air dryer 12 9...