P. 56 - Chap. 7 Start-up and operation
G
B
The following rules apply:
- Non-programmed cycles identified by the five hyphens that replace the time are not effective
-
Cycles for which the start and stop times coincide are not effective, similarly to those not
programmed
- If, in the last cycle programmed for a given day, the stopping time has been set to 24:00 and the first
cycle programmed for the next day has been set to 00:00, the control unit will keep the compressor
running during the change over at midnight from one day to the next
NOTE: remember that control via keyboard of the control unit always has priority over any program
control: this means that, if the program is to be effective, the K1-START button must be pressed setting
the compressor to “Stand-by progr. con.”. Similarly, the compressor can be stopped without any risk
of restart by the pre-set program pressing the K2-STOP key.
Therefore, to enable functioning with program control:
1) Select PROGRAM control
2) Select the programming method to be used (DAILY/WEEKLY)
3) Program the daily or weekly schedule selected
4) Press the K1-START key on the control unit to enable program control
7.4.2.7
DIAGNOSTICS menu
From the diagnostics menu, it is possible to check functioning of the INPUTS, OUTPUTS and the direction
of rotation of the compressor and fan. It is also possible to read the log of faults that have occurred on the
compressor.
These diagnostic functions should be used only by expert personnel with in-depth knowledge
of the compressor and how this operates.
Diagnostic TEST
To run the diagnostic TEST, comply with all the safety rules described in chapter 5
WARNING!!!
When carrying out the test, certain parts of the machine are powered (control coils) and
rotating parts are activated (motor, compressor, fan). The operator must therefore take all
the necessary precautions during these checks.
Error messages
The control unit saves all the faults that have occurred and which have caused stoppage of the machine
(alarms). The following data are save for each error message:
- Type of error (alarm)
- Time, day, date on which the alarm occurred
- Total hours and hours of load run when the fault occurred
These indications are displayed cyclically on the third and fourth lines of the display.
Содержание GENESIS Series
Страница 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Страница 2: ......
Страница 11: ...IX FORMULA 15 kW BA 69 Fig 17 Fig 18 PC PE SPA CF FA PF CT TRL VR BF PS ES EV FU MA RA RO MP PP VA FO FO VS SS...
Страница 12: ...X MODULO 5 5 7 5 kW Fig 19 Fig 20 FO FD FA SS ES FU MA RA RO PP MP PC PE SCE SF VA EV BF VT TRL CT PF VS PS...
Страница 14: ...XII MODULO 15 kW BA 69 Fig 23 Fig 24 PS PP PF MA FU RA RO ES VA FO FD VS SS MP CF FA SCE PE PC TRL VR BF CT EV...
Страница 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Страница 84: ...P 82 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines without air dryer 12 2...
Страница 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Страница 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Страница 87: ...P 85 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 5 5 15 kW Machines without air dryer 12 5...
Страница 88: ...P 86 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 5 5 15 kW Machines with air dryer 12 6...
Страница 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...
Страница 90: ...P 88 Chap 12 Diagrams G B Wiring diagram for component location 5 5 15 kW Machines without air dryer 12 8...
Страница 91: ...P 89 Chap 12 Diagrams G B Wiring diagram for component location 5 5 15 kW Machines with air dryer 12 9...