Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 38 -
1121
5
[Rada Home Fail]
Rada homing failed. Check
Rada limit sensor adjustment
and stepper motor
connection.
Rada limit never detected screw coming off of Rada.
Could be an issue with the inductive sensor or Rada
motor mount, wiring issue, stepper motor failure.
Manual Reset
[Disables Valves]
6
[Res Long Fill]
Reservoir taking too long to
fill. Verify correct operation of
top float sensor
Reservoir filling for a long time without top sensor being
triggered. This can be triggered if the plumbing does not
have adequate flow or if the water heater cannot keep up
resulting in a reduced flow. If this is the case, then adjust
the "Reservoir Max Fill Time" variable under "Timer
Adjustments" accordingly. Could also be a sensor/ wiring
failure.
Manual Reset
[Closes Reservoir
Fill]
7
[tub long fill]
Tub filling for too long. Verify
top water sensor is working
correctly.
The tub took significantly longer than expected to fill. Top
capacitive sensor likely the culprit. Check function/ wiring
or increase "Tub Max Fill Time" under "Timer
Adjustments" if the cause is slow plumbing.
Manual Reset
[Closes Tub Fill
Valve]
8
[res long drain]
Reservoir taking too long to
drain. Verify correct operation
of bottom reservoir float
sensor.
The bottom float does not reflect that tank has emptied
after a given amount of time. Could be sensor failure.
Manual Reset
[Prevents
reservoir pump
from running]
9
[UV Stuck On]
Light detected from UV lamps
after UV system deactivated.
Possible relay failure.
Light sensor indicate that UV lights didn’t turn off when
they should have. Could also be caused by relay getting
stuck in closed position (This is the case if UV lights are
truly on.) or by there being too much ambient light
behind the tub.
Auto Reset
10
[No Cold Supply]
Cold Supply Error
–
Can’t
bring down water temp.
Check cold supply and verify
pully secured to Rada shaft.
System unable to drop water temperature. Could be
caused by cold supply be turned off, loss in cold side
water pressure, or screw/ setscrew securing large pully to
Rada becoming loose. If large pully becomes loose it will
slip relative to brass shaft.
Auto/ Manual