Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 14 -
1121
™ UV Water Purification System (if applicable)
Your bathing system is equipped with the ™ UV Germicidal Water Purification System, an
electronic germicidal ultraviolet (UV) light disinfecting system.
When you operate the bathing system, the bathwater is continuously circulated through two ultraviolet
chambers, where the water passes over and around two UV lamps.
The UV light is monitored electronically, and indicator lights show that the UV light is sufficient to
disinfect.
The ™ UV Germicidal Water Purification System is
automatic; it turns on and off with the
Hydrologic™ Therapy System, a highly advanced whirlpool water flow system, and has no separate
controls.
Use only ultraviolet transmissible cleaners, disinfectants, soaps, and bath oils, such as Apollo’s Turbo
Clean
™ Pre
-Disinfectant Detergent, Cid-A-
L™ II Quaternary Disinfectant, Hygena™ Shampoo and Body
Wash, and Therasol™ Natural Bath Oil. Use of other cleaners, soaps, and bath oils is not recommended
and could compromise the ™ UV Infection Protection Syste
m.
Cleaning & Disinfecting Considerations
The Solares™ Smart Spa provides comprehensive infection control, featuring our UV water
purification, the bath chair embedded with BioGuard™ antimicrobial protectant
, and an automated
cleaning and disinfecting system.
Your Solares™ Smart Spa arrived with an Intro Pack which includes Turbo Clean™ Pre
-Disinfectant
Detergent and Cid-A-
L™ II Quaternary Disinfectant.
Turbo Clean™ is used after each bath to remove residue, bacteria, and gross soils.
Cid-A-
L™ II is
used after cleaning to effectively kill bath-borne bacteria, fungi, and viruses.
Your Solares™ Smart Spa is calibrated to dilute Turbo Clean™ and Cid
-A-
L™ II at the mixture stipulated
by the manufacturer’s instructions. Use of other cleaners and disinfect
ants is not recommended and
could compromise the overall process.
With Remedy® UV Infection Protection™ System
•
Always follow the Cleaning Procedure after every bath.
•
When equipped with UV water purification, it may not be necessary to follow the
Disinfecting Procedure after every bath in the same bathing session. Consult with your infection
control specialist or infection control policy to determine your disinfecting requirements.
•
For a Special Care Resident or in the event potentially infectious matter is released into the tub (e.g.
fecal matter, wound debridement, blood, mucus, etc.), consult infection control management to
determine if terminal disinfecting (Disinfecting Procedure) is required before using again.
•
Always follow the Disinfecting Procedure after the last bath of the bathing session.
Without Remedy® UV Infection Protection™ System
•
Always follow the Cleaning and Disinfecting Procedure after every bath.
Replacing Cleaning and Disinfecting Products
•
Remove the right-side access panel from the tub. Place product in the tray as indicated by the labels.
Содержание Solares Smart Spa
Страница 30: ......