Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 37 -
1121
DS Disinfection Solenoid
–
Solenoid valve that
routes water to Disinfecting line of DS system.
Tub Drain/ Res Drain/ Tilt Enable
–
Status of
primary activation relay of output.
Tub Drain/ Res Drain/ Tilt Direction
–
Status of
DPDT relay used for reversing the direction of
the output.
Reservoir Pump
–
Reservoir pump used for
pumping water out of the reservoir and into
the tub.
Remedy System
–
UV system.
Whirlpool Pump
–
Tub’s whirlpool pump.
Rada Motor On/ Off
–
enable/ disable status
of Rada Motor -
Should only show “On” if
Rada is being adjusted. When “On” is shown,
then you should not be able to move the Rada
easily.
Rada Motor Step
–
Turns on to move Rada
Motor one step.
Rada Motor Direction
–
direction Rada motor
is set to turn. ctrClk = counterclockwise.
Dock Release
–
Carrier latch release
mechanism.
Errors
Errors are displayed on the bottom of the maintenance screen and can be reset by hitting the “Reset
Error” button in t
he bottom right-hand corner of the screen. Manual Reset errors need to be manually
reset under maintenance, Auto Reset errors will automatically clear once the offending conditions
have passed, and Auto/ Manual Reset errors automatically clear, but can be manually cleared as well.
The effects shown in the below table describe the features that are disabled until the error is reset.
Error List:
ID
Error as shown on screen.
Expanded explanation
Type [effect]
1
[Tilt Sensor Error]
Tilt sensor not detecting tub.
Verify tilt sensor is working
and adjusted appropriately
and ensure the actuator is
functioning.
Means tub was able to raise longer than expected
without hitting the upper limit. Likely causes are poor
positioning of the tilt limit switch and limit switch/ wiring
issue.
Manual Reset
[Disables tub
from tilting
upward]
2
[Res Drain Error]
Reservoir not draining. Verify
that the reservoir slide valve
opens and that the top float
sensor is working correctly.
Float switches still show the tank as full after the tank has
been draining for a while. Likely float sensor or slide valve
problem.
Manual Reset
[Disables Drain
Pump]
3
[Therm Fault]
Thermometer Fault. Please
ensure the thermometer is
connected properly.
Unlikely resistance value was measured from the
manifold thermometer. Likely caused by the
thermometer being disconnected or wired incorrectly.
Auto Reset
[Disables Valves]
4
[Temp Over Limit]
Temperature over the limit.
Verify Rada cartridge
adjusted appropriately.
Rada unable to bring the water temperature down into
an acceptable range. Could be caused by the cold-water
supply being turned off.
Auto/ Manual
Reset [Disables
Valves]
Содержание Solares Smart Spa
Страница 30: ......