Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 36 -
1121
digital inputs and those on the right are
analog inputs. The digital inputs display “Low”
when the sensor is not triggered and “High”
when the sensor is triggered.
Docking Latch Sensor
–
The sensor that is
embedded in the docking latch itself. Shows
“High” if the latch is closed.
Docking Pin Sensor
–
The sensor protruding
from the front of the tub frame. This sensor
shows “High” when it detects the carrier
frame in front of it.
Tilt Limit Sensor
–
The limit switch is mounted
on the back of the tub frame. Shows “High”
when the tub tilts up and the upper frame
hits the sensor.
Rada Home Sensor
–
The sensor connected to
the Rada. This sensor displays “High” when it
detects the screw protruding from the large
pulley.
Middle Water Lvl Sensor
–
Water sensor
located next to left side jet.
Top Water Lvl Sensor
–
Water sensor located
next to left overflow.
Transfer Release Button
–
metallic button by
the right side of door used for releasing
carrier.
Top Reservoir Float
–
Top float sensor in the
reservoir tank.
Should show “Low” if
a sensor
is disconnected or if the water is above the
sensor.
Bot Reservoir Float
–
Bottom float sensor in
the reservoir tank.
Should show “Low” if
the
sensor is disconnected or if the water is above
the sensor.
Manifold Therm
–
Top value displays raw
thermistor input and the bottom value
displays temperature in Fahrenheit. (values
are for the thermistor in the manifold for
filling.)
Reservoir Therm - Top value displays raw
thermistor input and the bottom value
displays temperature in Fahrenheit. (values
are for the thermistor in the bottom reservoir
float.)
Top/ bottom UV Sensor
–
top value is raw
input in microvolts & bottom value is value in
volts.
Outputs Screen:
Click on the
“Outputs” button in
the bottom
right of the inputs screen to get to the
outputs screen. The outputs screen shows the
status of each output and allows you to force
output on by pushing the arrow next to the
output. The arrows are small, so a plastic
stylus is recommended for operating them.
Tub Fill Solenoid
–
¾” solenoid valve that
allows water to flow into the bottom of the
tub from the manifold.
Reservoir Fill Solenoid
–
solenoid valve that
allows water to flow into the reservoir tank.
Shower Wand Solenoid
–
Solenoid valve that
allows water to flow to shower wand.
DS Rinse Solenoid
–
Solenoid valve that routes
water to the rinsing line of DS system.
DS Cleaner Solenoid
–
Solenoid valve that
routes water to the cleaning line of the DS
system.