14
Operation
WARNING!
Do not use a product that is only partly assembled or
assembled with damaged parts!
Cold Start
(low environment temperature -20°C)
If it has never started before your start or the engine stops for a while (more than
20min) after your start, follow below steps
.
1
2
3
Rotate fuel lever to
“ON”
Set choke to the CLOSE
Insert the ignition key
fully. Do not rotate it.
4
5
Pull recoil starter
handle.
WARNING! Allow the cable
to return slowly and in a
controlled manner each time it is
pulled.
Press primer 3
times
6
7
Electric start:
①
connect extension cord to start
and plug extension into 120V 3-wire, grounded
outlet
②
press starter button on engine until
engine starts
③
remove the connect extension
cord from the grounded outlet.
NOTE: DO NOT operate starter more than 15 seconds per
minute, as overheating and damage can occur. (If engine does
not start, refer to TROUBLESHOOTING)
Run idle for
20-30
seconds
8
9
Move gradually the choke to OPEN
position
Operate
NOTE: When moving the choke to the OPEN
position and the engine speed gets
inconsistent. Then move the choke to the
middle position to allow additional time for warming up.
After warm up, move the choke to the OPEN position