Receiver CSV File Format & Parameter Description
Don’t change field sequence. First row field name can be changed. Use comma to divide field when saving
CSV file.
Field / Parameter
Description
Parameter Value
IP
Receiver IP
ie. 169.254.8.105 192.168.1.25
ID
Receiver ID, No duplicate
Number only, start form 1
Group
Receiver Group name
English, German, French, Latin, Chinese,
Japanese, _
Codename
Receiver Codename
English, German, French, Latin, Chinese,
Japanese, _
Video channel
Video channel
Number only, start from 1
Audio channel
Audio channel
Number only, start from 1
Video channel
USB channel
Number only, start from 1
RS232 channel
RS232 channel
(RS232 mode must be set Pass-Thru)
Number only, start from 1
IR channel
IR channel
Number only, start from 1
Output Video Format
Assign Receiver HDMI output video
format
Parameter value options:
auto_detect : Auto detect TV/Display EDID
pass-thru : same as HDMI input at sender
0 : same as HDMI input at sender (pass-
thru)
2160p30 : 2160p30Hz
2160p25 : 2160p25Hz
2160p24_VIC_103 : 2160p24Hz VIC 103
2160p24_VIC_98 : 2160p24Hz VIC 98
2160p24_VIC_93 : 2160p24Hz VIC 93
1080p60 : 1080p60Hz
1080p50 : 1080p50Hz
1080p24_VIC_72 : 1080p24Hz VIC 72
1080p24_VIC_32 : 1080p24Hz VIC 32
1080i60 : 1080i60Hz
1080i50 : 1080i50Hz
720p60 : 720p60Hz
576p50 : 576p50Hz
480p60 : 480p60Hz
1920x1200 : 1
1920x1080 : 1
1680x1050 : 1680x1050@60Hz
1440x900 : 1
1400x1050 : 1
1366x768 : 1
800x600 : 8
Enable/Disable USB
Pass-Thru
USB Pass-Thru between Sender and
Receiver
y/n only (Lower letters only)
y : disable USB Pass-thru
n : enable USB Pass-thru
Device Control ID
To match Device ID in Device Control
CSV File
Number must be match m
atch Device ID in
Device Control CSV File
RS232 mode
IP Command
Pass-Thru between sender and
Receiver
Parameter value options:
y : IP Command
n : Pass-Thru
RS232 baudrate
RS232 baudrate setting
Parameter value options:
115200/57600/38400/28800/19200/14400/9
600/4800/2400/1200/600/300
14