16
5 Assembly
5.1 Handle unit
WARNING - The handle unit must be securely fixed with the locking screw so that it is safely
joined to the climbing unit!
WARNING - The climbing unit mount may only be adjusted by the
manufacturer, the AAT field
service or an authorised specialist dealer!
A 9-pin sub-D coupling in the receptacle provides the electrical connection.
Connect the handle unit and
the climbing unit to each
other.
»
The mount must be aligned
parallel to the housing.
Secure the connection with
the locking knob for the
stanchion tube.
Both units must have been
securely joined.
5.2 Battery pack
WARNING - The battery pack must be fixed and locked to prevent immediate detachment!
Assembly
Insert the battery
pack into the opening
provided in the climbing unit.
»
The battery locking device
is activated automatically.
Disassembly
Release the
locking device.
»
Press the release button on
the climbing unit downwards,
then pull out the battery
pack.
i