Frequently Asked Questions
DECT
222
19.4
DECT
Note:
In the following explanations it is assumed that a U
pn
interface card has been installed (in an OpenCom 130 or an
OpenCom 150).
Question: The LED of the RFP 22 / 24 base station is flashing, but none of the
DECT devices is functioning.
Make sure the terminal setting for the corresponding U
pn
port is set to an RFP 22 /
24 base station (
Configurator
,
Telephony: Ports: U
pn
menu).
If multiple RFP 22 / 24 base stations are installed, the blinking LED indicates that
synchronisation is not finished.
Question: The LED of the RFP 22 / 24 base station is continuously lit up, but
one of the cordless DECT devices is indicating “No connection”.
You have not registered this DECT device. Configure a port in the
Configurator
and start the enrolment procedure (
Telephony: Devices: DECT Phones
menu).
Question: Is it possible to increase the time for the enrolment procedure?
You must manually enter the IPEI of the DECT device in the
Configurator
. The
enrolment time is then increased to one hour (
Telephony: Devices: DECT Phones
menu).
Question: Another manufacturer’s DECT device is not functioning.
Check whether the DECT device supports the DECT GAP standard. In the
Configu-
rator
, also make sure
GAP
is set for this DECT device (
Telephony: Devices: DECT
Phones
menu).
Question: The startup procedure of the DECT base stations take a long time?
What is the reason?
This behaviour may indicate a problem with the reference clock. Refer also to
are some of the causes for problems when sending and/or receiving faxes?