Voice over IP (VoIP)
SIP Telephony
118
name and correct password is always successful. Only when a connection is estab-
lished is there an attempt made to occupy a licence under the SIP log-on. If all
licences are occupied currently, the SIP subscriber can only make emergency calls.
Note:
If the technical log-on is not successful due to an in-
correct user name or incorrect password, the SIP subscriber
cannot establish any connections – no emergency calls ei-
ther.
When a SIP subscriber logs off, when terminating the programme, for example, the
associated licence will become available immediately. A licence is also made
available when a SIP subscriber’s regular status query is not conducted. The
internal clock for automatic log-out is determined by the
Profile
assigned under
Telephony
:
Devices
:
VoIP Phones
. The (
Keepalive
) internal clock setting is
located on the
Telephony
:
Extended
:
VoIP profile
page.
Detailed information on the current licence assignment and on logged-on SIP sub-
scribers is located on the
System Info
:
Telephony
:
SIP phones
page. This page is
where you can reset licence assignment at any time by clicking on
Reset licences
.
Technical Notes
The names of settings for the various SIP telephones or SIP programmes are not
uniform unfortunately. Please refer to the
(Help)
on the
Telephony
:
Devices
:
VoIP
Phones
page and the following notes when configuring SIP subscribers:
■
The “REGISTER” SIP message must be sent to the IP address of the
OpenCom 100 using the 5060 destination port. For SIP subscribers, this setting
is frequently located under “SIP Server” or “SIP Settings” with the terms
“Domain”, “Server IP” and “Server Port”.
■
The “REGISTER” SIP message must contain a valid user name and the appro-
priate password (the
User name
and
Password
fields in the
Configurator
under
User Manager
:
User
). For SIP subscribers, this setting is frequently
located under “SIP User Settings” or “SIP Account” with the terms “Authori-
zation User” and “Password”.
■
The “REGISTER” SIP message also contains a SIP-URI in the spelling for e-mail
addresses, for example
"Displayname" <sip:[email protected]>
.
The text portion of the SIP-URI (“Display Name”) is not evaluated at log-on from
the OpenCom 100. The series of characters before “@” is the “User Name” or
“SIP Username”. The internal call number of the user must always be used here
(the
Ph.No.
field in the
Configurator
under
User Manager
:
User
). The series of
Содержание OpenCom 100
Страница 1: ...130 OpenCom100 131 150 Mounting and Commissioning User Guide...
Страница 10: ...8...
Страница 240: ...Index 238 X XML 124...
Страница 241: ...Index 239 Notes...
Страница 242: ...Index 240 Notes...
Страница 243: ......
Страница 244: ...www aastra com As of 19 07 2009 Subject to changes...