www.a-ts.cn A-TS Technology RT20
67
PA44
★
Pulse command
function selection
00000b-111
11b
00000b
bit0,high-speed
pulse selection
bit1, get it by
hand function
P
PA45
★
The number of bits of
the absolute encoder
per revolution
0-30
0
Set to 0, means
the default is 17
bits
ALL
PA47
The waiting time for
enabling
disconnection when
the motor is stationary
0-5000
0
ms
ALL
PA48
The waiting time for
electromagnetic
brakes to brake while
the motor is running
0-5000
50
ms
ALL
PA49
Brake action speed
when the motor is
running
0-3000
100
rpm
ALL
PA50
The delay of the
brake opening when
the motor is enabled
0-3000
20
ms
ALL
PA51
★
Braking resistor
selection switch
0-1
0
ALL
PA52
Position command
smoothing time
constant
0.0-100.0
0.0
ms
P
PA53
Lower 5 bits input
terminal forced ON
00000b-111
11b
00000b
Binary
ALL