www.a-ts.cn A-TS Technology RT20
50
Figure 5-4 PLC control wiring diagram
Wiring diagram of the CNC control
COM
7
SRV-ON
29
RT20 Servo Drive
DC
12-24V
Servo enabled
(SON)
CN3
U
V
W
CN4
/CN5
U
V
W
Servo Motor
ENC
M
NOT
8
POT
9
ALM+
37
ALM-
36
PULS
+
3
PULS- 4
SIGN+ 5
SIGN-
6
CZ
19
GND
25
CCW
CCWL
CW
CWL
Servo alarm output
Position command PULS
Position command SIGN
Open-circuit Z signal
output
Encoder signal
ground GND
PE
50
Command cable
shielded ground
Note1:
The X1 DI / DO port function
can be defined by t h e Fn
paramete r . I n this diagram , the
default values are used , and they
can be changed by user.
Note 2:
X2 is the encoder interface,
If the encoder type is different, the
wiring is different. Please refer to
Section 3.2.4.
Figure 5-5 CNC control wiring diagram
ATTENTION
Command cables must be shielded with two legs. One set of twisted pair is
used for pulse and direction.
By modifying PA19, the command pulse signal can be filtered to remove
interference noise.
5.5.2 Position command
Parameters related to the position command
Table 5-4 Parameters related to position command