www.a-ts.cn A-TS Technology RT20
43
5 Commissioning and Running
Trial running without load
The purpose of trial running is to confirm whether the following items are
correct.
The servo drive power supply wiring
The servo motor wiring
Encoder wiring
The servo motor running direction and speed
5.1 Wiring and inspection
Before power on, please check the motor.
No load on the motor or motor shaft. Please disconnect the couplings if
it is already installed on the machine.
The motor must be fixed, or the ACC/DEC will move the motor.
Do the wiring as per the following diagram, and check the following
before power on.
Is the wiring correct? Especially whether the L1 / L2 / L3 wiring
and U / V / W have the one-to-one correspondence with the
motor?
Is the input voltage correct?
Is the encoder cable wiring correct?