background image

User Manual CLASSIC 514 

 

August 2023

 

 

 

File: User Manual_CLASSIC 514_rev5.docx 

44 

 

9.4  Cleaning of Accesories 

9.4.1  Foot switch 

The  general  cleaning  instructions  (see  above)  must  be  respected  in  any  case.  When 
cleaning  the  foot  switch,  prevent  the  penetration  of  water  or  cleaning  agents.  Never 
place the foot switch in water or cleaning agent, this could lead to a short circuit.  

9.4.2  Laser safety goggles 

The cleaning instructions provided with the laser safety goggles must be respected.  

In  general,  never  use  chemicals  for  cleaning  that  could  damage  the  coating  fo  the 
glasses. Always use soft cloths that do not leace scratches on the surface 

9.4.3  Slit Lamp 

You  can  find  detailed  information  on  the  care  and  maintenance  of  the  slit  lamp  in  the 
accompanying manual. It is essential to follow these instructions. 

9.4.3.1  Slit Lamp mirror 

If necessary, clean the slit lamp mirror with a suitable lens brush. After dedusting, clean 
the mirror with Kodak lens cloths and a few drops of pure acetone. Do not use the cloth 
dry,  otherwise  the  mirror  will  be  scratched.  Press  only  lightly  so  that  the  mirror  is  not 
adjusted. Do not rub more than once or twice. Heavy rubbing only spreads the dirt and 
causes scratches. 

9.4.3.2  Dust Cover 

After each use, the dust cover and the red display protective cover should be replaced to 
keep the surfaces clean. 

9.4.3.3  Testing the Slit Lamp Focus

 

1)  Use the focus rod and insert it into the hole in the slit lamp axis. Follow the slit lamp 

manual that comes with the device. 

2)  Turn on the laser. Make sure that the laser is not triggered during this time. The 

laser must be in the READY mode. Center the aiming beam in the middle of the 
visual field on the focus rod. 

3)  Check that the aiming beam is circular and symmetrical. 

A  disturbed  target  beam  can  be  an  indication  of  a  faulty  system;  thus,  the  aiming 
beam can be a tool to check the integrity of the system. 

 

 

 

Содержание CLASSIC 514

Страница 1: ...User Manual A R C Laser GmbH 0123 Bessemerstr 14 D 90411 N rnberg Tel 49 911 21779 0 Fax 49 911 21779 99 info arclaser de www arclaser de...

Страница 2: ...Bessemerstr 14 D 90411 N rnberg Tel 49 911 21779 0 Fax 49 911 21779 99 service arclaser de Copyright A R C Laser GmbH All rights reserved This document contains confidential and copyrighted informatio...

Страница 3: ...ective housing 15 4 10 Connectors and switches 15 4 11 External interlock switch 16 4 12 Safety Shutter Aiming beam 16 4 13 Manual reset 16 4 14 Reset by power failure 16 4 15 Lables and markings 17 4...

Страница 4: ...used with the L ORD 41 8 2 2 Classification 41 9 Maintenance 42 9 1 Introduction 42 9 2 Safety Check STK 42 9 3 Care by the user 42 9 4 Cleaning of Accesories 44 9 4 1 Foot switch 44 9 4 2 Laser safe...

Страница 5: ...If you have any further questions regarding the safety or the use of the device or regarding the laser and laser radiation please contact A R C Laser GmbH 1 1 Marking and symbols The symbol Attention...

Страница 6: ...n Infection inflammation iritis from iridotomy or trabeculoplasty posterior synechiae from iridotomy anterior synechiae from trabeculoplasty bleeding not persistent IOP increase after treatment macula...

Страница 7: ...on arises To improve this effect the laser is equipped with a resonator in our case the photon emitting semiconductor itself The plan parallel properties of the crystal with its high index of refracti...

Страница 8: ...750 hPa During storage a temperature range of 5 C to 40 C must be maintained The environment air must be dry and clean The relative humidity during transport and storage must be between 5 and 85 A T...

Страница 9: ...GmbH be sure to use the intended transport packaging Normally the CLASSIC is delivered together with the slit lamp For transportation the device is packed as follows The transport packaging is design...

Страница 10: ...n use it should be covered to prevent contamination For this purpose a suitable dust cover is included The wiring must be installed so that there are no tripping hazards or other hazards All control e...

Страница 11: ...matted In the area of laser use only matted non reflective and non flammable instruments and materials should be used 3 3 Electrical connection The laser is operated with a DC voltage of 24 V The pow...

Страница 12: ...should enclose applicable legal regulations and provisions with the device and inform the staff accordingly If the device is operated outside Germany provisions of the American National Standard Offic...

Страница 13: ...esulting from internal reflections on the glasses Therefore we encourage you to wear laser safety glasses which also guarantee a full protection to the side parts The eye safety of the operator is ens...

Страница 14: ...e irradiance is equal to the exposure limit value of the cornea of the eye The NOHD identifies the danger area within which there is a risk of damage to the health of the eye if you look directly into...

Страница 15: ...tances in concentrations whose placing on the market is prohibited according to the applicable requirements of Directive 2015 863 EU RoHS 3 4 9 Protective housing The CLASSIC 514 laser has a protectiv...

Страница 16: ...standard which can be replaced by a door interlock switch The laser switches off when the door is opened In addition the laser cannot be switched to the READY mode when the door is open An error messa...

Страница 17: ...gs in accordance with European and worldwide guidelines to prevent the laser user from being exposed to laser radiation by negligence The following labels can be found on the CLASSIC 514 Type plate 1...

Страница 18: ...80 hPa and 750 hPa The following environmental conditions must be met Ambient temperature 18 C to 35 C Relative humidity 75 4 17 Electromagnetic compatibility The CLASSIC 514 laser system meets the EM...

Страница 19: ...es from portable or mobile wireless communication devices please refer to Chap 18 3 ELECTROMAGNETIC PROTECTION II and 18 4 RECOMMENDED PROTECTION DISTANCES RFID systems shall not be used at separation...

Страница 20: ...instruction from an A R C Laser GmbH employee or by an authorized representative when installing the device During instruction the use of laser safety glasses and laser safety will be specifically add...

Страница 21: ...accessories transduce and services other than those which the A R C Laser GmbH has determined or provided may result in increased electromagnetic interference or reduced electromagnetic immunity of th...

Страница 22: ...CLASSIC 514 The laser radiation which is coupled in the fiber connector is re directed through the zoom optic into the beamcombiner For using the laser with the slit lamp the beamcombiner needs to be...

Страница 23: ...ems are duly packed by A R C Laser GmbH and supplied together with the corresponding accompanying documentation of the respective manufacturers This accompanying information has to be respected Before...

Страница 24: ...to malfunctions The laser is in the READY mode during treatment If you need to interrupt the laser must be returned to STANDBY mode The device must always be switched off when unattended to prevent o...

Страница 25: ...d herein may result in hazardous laser radiation exposure 1 Laser Stop 7 Adjustment of pulse length with plus minus 2 Laser READY LED 8 Adjustment of pulse pause with plus minus 3 Laser READY button 9...

Страница 26: ...Starting the laser The CLASSIC 514 is used together with a slit lamp The device is connected via a power supply to the lifting table To start the device and the slit lamp switch on the main switch und...

Страница 27: ...apter 6 4 1 to change the password To enter the password turn the rotating wheel to the right The selected number is confirmed by pressing the rotating wheel Afterwards a star in the upper code line m...

Страница 28: ...y pulse pause settings In the factory settings the right arrow keys can be used to change the frequency Hz up to 10 Hz Following values are possible 1 Hz to 5 Hz in 1 Hz steps 10 Hz and SP signle puls...

Страница 29: ...to 15 The device emits 5 pulses per 10 ms which means 25 pulses when chosing 50 ms 50 pulses when chosing 100 ms and so on The percentual values 5 10 15 correspondend to the share of the delivered po...

Страница 30: ...eel changes the respective value If an icon is darkened it is active and the values can be changed 1 Display brightness can be adjusted from 25 100 in 5 steps 2 Audio frequency can be adjustet from 0...

Страница 31: ...bol redirects you into another sub menu This menu contains information concerning your CLASSIC 514 Furthermore it informs about the last occurring error which you can communicate to the service person...

Страница 32: ...rt at a low level and then increase energy to the target during treatment Fix the patient s eye with a contact glass and focus the target beam into the eye to be treated Select the necessary beam inte...

Страница 33: ...will be pressed during treatment the same error message appears on the screen and the device cannot be used anymore A T T E N T I O N In general the Laser Stop should only be used in emergencies 6 9...

Страница 34: ...Audio pitch 0 100 Back in APL Mode Audio volume 10 100 Delete during entering password Aiming beam brightness 1 100 Accept during entering password Info menu Temperature too high Leave menu Temperatur...

Страница 35: ...Please use the packaging material of A R C Laser GmbH only to protect the device from damages during transport The L ORD should only be stored and transported in a temparture range between 10 C and 60...

Страница 36: ...e L ORD is used together with the CLASSIC 514 With regard to ambient conditions such as humidity and air pressure please refer to chapter 4 16 Due to the internal design of the L ORD a maximum tempera...

Страница 37: ...tand Make sure that the connection hose with the control cable of the L ORD is which is firmly attached to the connection hose is additionally connected to the red socket at the rear panel of the CLAS...

Страница 38: ...aser can only be set into READY mode if the L ORD swung in correctly in the working position If the L ORD is not correctly in working position an error message occurs Please check the position of the...

Страница 39: ...tion of the beam can be adjusted via this adjusting wheel Vertical Alignment The vertical position of the beam can be adjusted via this adjusting wheel Deflection mirror The deflection mirror is used...

Страница 40: ...has been developed according to the latest technical knowledge We have set the product life to 7 years In addition the availability of the psare parts is guaranteed by us within a period of 10 years A...

Страница 41: ...htness Power transmission coupled in a slit lamp with 62 5 m fiber 8 1 3 Electrical Connection Data Power supply connection values 100 240 V 50Hz 60Hz 1 06 0 45 A 8 1 4 Classification Laser class work...

Страница 42: ...be subjected to a safety check STK by trained personnel Scope of Safety Check STK Visual Check Laser marking laser class max Power wavelength Information signs warning signs properly and completely at...

Страница 43: ...s according to the manufacturer of the disinfectant the disinfectant should be suitable for wipe disinfection of surfaces the disinfectant should be based on alcohol and or quaternary compounds the di...

Страница 44: ...ssary clean the slit lamp mirror with a suitable lens brush After dedusting clean the mirror with Kodak lens cloths and a few drops of pure acetone Do not use the cloth dry otherwise the mirror will b...

Страница 45: ...tem check and have to be checked by the user Problem Proable error Troubleshooting No aiming beam visible Laser is in STANDBY mode Aiming beam is only visible when the laser is in READY mode Change to...

Страница 46: ...regulations must be respected for proper disposal Under no circumstances should the device be disposed of with domestic waste A R C Laser GmbH is happy to assist with the disposal of the system Costs...

Страница 47: ...s that are returned during the warranty period at the express request of A R C Laser GmbH must be confirmed in writing by A R C Laser GmbH Detailed packaging instructions and information on how to ret...

Страница 48: ...nity tests Compliance Electromagnetic environment guideline RF Emissions CISPR 11 150 kHz 30 MHz EN 55011 Group 1 Class B The laser uses RF energy exclusively for its internal function Hence RF emissi...

Страница 49: ...agnetic fields with energetic design frequencies 30 A m 50 Hz or 60 Hz IEC 61000 4 8 Magnetic fields at the grid frequency that are usuallty available in professional healthcare facilities may be used...

Страница 50: ...Power interruption 0 UT 250 300 cycles at 0 and 180 level IEC 61000 4 11 Only the voltage of a typical professional healthcare facility may be used It is recommended to use an uninterruptible power s...

Страница 51: ...d no closer than 30 cm 12 inches to any part of the CLASSIC 514 including cables specified by the manufacturer Otherwise degradation of the performance of this equipment could result The field strengt...

Страница 52: ...cation device as stated below Test frequency MHz Frequency band MHz Radio service Modulation Maximum performance W Distance m Immunity test level V m 385 380 to 390 TETRA 400 Pulse modulation 18Hz 1 8...

Страница 53: ...User Manual CLASSIC 514 August 2023 File User Manual_CLASSIC 514_rev5 docx 53 Notes...

Страница 54: ...User Manual CLASSIC 514 August 2023 File User Manual_CLASSIC 514_rev5 docx 54 Notes...

Страница 55: ...User Manual CLASSIC 514 August 2023 File User Manual_CLASSIC 514_rev5 docx 55 Notes...

Страница 56: ...A R C Laser GmbH Bessemerstr 14 D 90411 N rnberg Tel 49 911 21779 0 Fax 49 911 21779 99 www arclaser de...

Отзывы: