Step 6:

Connect the Tempera-
ture and Pressure (T&P) 
Relief Valve/Pipe

Most T&P Relief Valves are pre-
installed at the factory. In some cases, 
they are shipped in the carton and 
must be installed in the opening 
marked “T&P Relief Valve” and accord-
ing to local codes.

Figure 25 -

Temperature and Pressure Relief Valve

WARNING! To avoid serious injury 

or death from explosion, install a T&P 
Relief Valve according to the following 
instruc  ons:

1

If the T&P Relief Valve was not 
factory installed, install the 
new T&P Relief Valve that 

came with your water heater. Do not 
reuse an old T&P Relief Valve. 
• 

 The discharge pipe should be at 
least 3/4” inside diameter and 
sloped for proper drainage. Install 
it to allow complete drainage of 
both the T&P Relief Valve and the 
discharge pipe.

Figure 26 -

Temperature and Pressure Relief 

Valve Pipe

• 

 The discharge pipe must not be 
smaller than the pipe size of the 
T&P Relief Valve. The pipe must 
also be able to withstand 250°F 
(121°C) without distor  on. Use 
only copper or CPVC pipe.  Do not 
use any other type of pipe, such as 
PVC, iron, 

fl

 exible plas  c pipe, or 

any type of hose.

• 

 Terminate the discharge pipe a 
maximum of six inches above a 

fl

 oor drain or outside the building. 

Do not drain the discharge pipe 
into the drain pan; instead pipe it 
separately to an adequate drain. 
In cold climates, terminate the dis-
charge pipe inside the building to 
an adequate drain. Outside drains 
could freeze and obstruct the 
drain line—protect the discharge 
pipe from freezing.

• 

 Do not place any valve or other 
restric  on between the tank and 
T&P Relief Valve. Do not cap, 
block, plug, or insert any valve 
between the T&P Relief Valve and 
the end of the discharge pipe. Do 
not insert or install any reducer in 
the discharge pipe.

Step 7:

Install Shuto

  and Ther-

mosta  c Mixing Valves

1

If one is not already installed, 
install a manual shuto

  valve 

in the cold water line that 

supplies the water heater. Install the 
shuto

  valve near the water heater so 

that it is readily accessible. Only use a 
full-

fl

 ow ball or gate valve compa  ble 

with potable water. 

2

Install a Thermosta  c Mixing 
Valve at each point-of-use (for 
example, kitchen sink, 

bathroom sink, bath, shower) per the 
valve manufacturer’s instruc  ons.

Figure 27 -

Install Thermostatic Mixing Valves at 

each point where hot water will be used.

WARNING! Even if the water 

heater’s thermostat is set to a rela-

 vely low temperature, hot water can 

scald. Install Thermosta  c Mixing 
Valves at each point-of-use to reduce 
the risk of scalding.

Содержание XCR-40-LP

Страница 1: ...on or service can damage the water heater your house and other property and present risks including fire scalding electric shock and explosion causing serious injury or death Do not store or use gasol...

Страница 2: ...t to cold water supply Hot water line T P relief valve Cold water shut o Dra hood T P discharge pipe Drain pan discharge pipe Metal drain pan Gas control valve thermostat Cold water line Gas supply sh...

Страница 3: ...uc ons is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of thi...

Страница 4: ...ake water hot enough to cause severe burns instantly resul ng in severe injury or death Feel water before bathing or showering To reduce the risk of scalding install Thermosta c Mixing Valves temperat...

Страница 5: ...on if you suspect flammable vapor have accumu lated inside or outside the appliance Immediately call a qualified person to inspect the appliance Water heaters subjected to a flammable vapors inci den...

Страница 6: ...odorless gas that is a by product of burning of fuels such as coal wood charcoal oil kerosene propane and natural gas Breathing excessive and abnormal amounts of carbon monoxide can cause carbon monox...

Страница 7: ...al plumbing supplier with compres sion fi ngs that don t require soldering This kit includes two 12 flex water lines two compression fi ngs an 18 flexible gas line two nipples and Teflon tape For home...

Страница 8: ...e you will need to conduct the vent dra test on pages 23 24 when installa on is finished If there is not enough ven la on you will need to ven late with outside air Check for Chemicals Installa ons wh...

Страница 9: ...or horizontal ducts B2 Determine type of ven la on There are several types of ven la on that can be used 1 Direct to outdoors 2 Ver cal ducts 3 Horizontal ducts 4 Single opening not recom mended must...

Страница 10: ...ension of no less than three inches All screens must have mesh or larger Moveable louvers must be locked open or interconnected with the equipment so that they open au toma cally during opera on Keep...

Страница 11: ...l spaces or any confined or inaccessible loca on Single wall vent pipe cannot pass through any interior wall Clearance to Combus ble Materials The vent pipe cannot pass through any ceiling floor firew...

Страница 12: ...m with type B double wall vent pipe Figure 9 Venting through a chimney with type B double wall vent pipe Gas Piping Gas piping must be installed accord ing to local and state codes or in the absence o...

Страница 13: ...at ing appliances when used to supply potable water Solar Installa on If this water heater is used as a solar stor age heater or as a backup for the solar system the water supply temperatures to the w...

Страница 14: ...s water pressure Locate your home s Pressure Reduc ing Valve PRV on the main incoming cold water supply line and adjust the water pressure control to between 50 and 60 psi If your home does not have...

Страница 15: ...eaks and can shut o the water heater s water supply if a leak occurs Install a metal drain pan available at your local plumbing supplier under the water heater to catch condensa on or leaks from the p...

Страница 16: ...If the water heater is installed di rectly on carpe ng it shall be in stalled on a metal or wood panel extending beyond the full width and depth of the water heater by at least 3 in 76 2mm in any dir...

Страница 17: ...flat blade screwdriver open the drain valve Sediment build up in the bo om of the water heater may hinder or prevent draining Figure 20 Draining the old water heater 8 Also open a hot water faucet to...

Страница 18: ...that extends beyond the dimen sions of the water heater width and depth by at least 3 inches 76 2 mm in any direc on If the water heater is installed on carpet in an alcove or closet the en re floor...

Страница 19: ...las c pipe or any type of hose Terminate the discharge pipe a maximum of six inches above a floor drain or outside the building Do not drain the discharge pipe into the drain pan instead pipe it separ...

Страница 20: ...g the water heater for service or replacement con nect the water pipes with a coupling called a union We recommend using a dielectric type union available at your local plumbing supplier Dielec tric u...

Страница 21: ...tor at the nearest hot water faucet This allows debris in plumbing system to be washed out of the pipes 2 Turn the cold water supply back on and fill the tank 3 Open a hot water faucet and allow the w...

Страница 22: ...ith large amounts of lint dust etc If so the air filter or flame arrestor located on the bo om of the water heater will need to be cleaned more o en Combus on Air Supply and Ven la on Adequate air sup...

Страница 23: ...three seconds Wait 10 minutes between ligh ng a empts 7 A solid Status Light means the pilot was lit but is now o Release the gas control knob and wait 10 minutes Once the Status Light goes out repea...

Страница 24: ...own as smelly water and can reduce the levels of bacteria that cause water borne diseases Water usage pa erns as well as heat from sources such as solar collectors ambient air and the pilot light can...

Страница 25: ...ot water is simply not warm enough there are several possible causes Faulty Thermosta c Mixing Valve in a faucet or shower control check other faucets in the house for hot water Water heater s capacit...

Страница 26: ...Valve or discharge pipe and do not operate the water heater without a func oning T P Relief Valve this could cause an explosion Water Pressure too High High water pressure can cause the T P Relief Va...

Страница 27: ...Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING...

Страница 28: ...the drain valve and place the other end of the hose in a drain outside or in buckets Note that sediment in the bo om of the tank may clog the valve and prevent it from draining If you can t get the t...

Страница 29: ...properly perform this visual inspec on or if the burner needs to be cleaned get help from a qualified person T P Relief Valve Maintenance Figure 45 T P Relief Valve Read and follow the opera ng and an...

Страница 30: ...d a 4 sec on of gas pipe into the inlet and use it to turn the FVIR Safety System Opera onal Checklist TROU BLESHOOTING CHART gas control valve thermostat counterclockwise Do not use pipe wrench or eq...

Страница 31: ...Residen al Standard Gas Water Heater Use and Care Guide 31 NOTES NOTES...

Страница 32: ...32 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 33: ...Residen al Standard Gas Water Heater Use and Care Guide 33 NOTES NOTES...

Страница 34: ...34 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 35: ...wire lead 11 OUTER DOOR 12 PILOT THERMOPILEASSEMBLY KIT 13 FINAL BURNER ASSEMBLY 14 MANIFOLD DOOR GASKET 15 BASE RING AIR FILTER REPAIR PARTS LIST 4 6 1 8 10 9 11 15 5 7 8 Replacement parts may be ord...

Страница 36: ...embly which contains the burner orifice manifold tube gasket door pilot tube thermopile manifold component block with retainer clip thermal switch and pilot assembly Natural Gas Low Nox or L P Item 14...

Отзывы: