background image

 4 • Residen  al Standard Gas Water Heater Use and Care Guide

S

AFETY

 4 • Residen  al Standard Gas Water Heater Use and Care Guide

IMPORTANT SAFETY INFORMATION

T

o reduce the risk of property 
damage, serious injury or death, 

read and follow the precau  ons below, 
all labels on the water heater, and 
the safety messages and instruc  ons 
throughout this manual.

RISKS DURING
INSTALLATION AND 
MAINTENANCE

Li  ing Risk

WARNING! 

The 

water heater is heavy. 
Follow these precau-

 ons to reduce the 

risk of property damage, injuries from 
li  ing or impact injuries from dropping 
the water heater.

• 

 Use at least two people to li   the 
water heater.  

• 

 Be sure you both have a good grip 
before li  ing.

• 

 Use an appliance dolly or hand 
truck to move the water heater.

Explosion Risk

WARNING! Read the water heater’s 

data plate to determine the type of 
gas required. Failure to follow these 
instruc  ons can result in serious injury 
or death from explosion, 

fi

 re or 

carbon monoxide poisoning.

• 

 Do not connect a natural gas water 
heater to an L.P. gas supply.

• 

 Do not connect an L.P. gas water 
heater to a natural gas supply.

• 

Use a new CSA approved gas 
supply line.

• 

 Install a shut-o

  valve on the gas 

supply line.

Gas Pressure

WARNING! The gas supply pressure 

must not exceed the maximum supply 
pressure as stated on the water 
heater’s data plate. The minimum 
supply pressure is for the purpose of 
input adjustment. L.P. gas supply 
pressure must not exceed 13” water 
column. Have a quali

fi

 ed person 

(licensed plumber, gas company 
personnel, or authorized service 
technician) check for proper L.P. gas 
pressure. L.P. gas pressures exceeding 
13” water column can result in serious 
injury or  death from explosion or 

fi

 re.

RISKS DURING
OPERATION 

Scalding Risk 

This water heater 
can make water hot 

enough to cause severe burns instantly, 
resul  ng in severe injury or death. 

• 

Feel water before bathing or 
showering.

• 

To reduce the risk of scalding, 
install Thermosta  c Mixing Valves 
(temperature limi  ng valves) at 
each point-of-use. These valves 
automa  cally mix hot and cold 
water to limit the temperature at 
the  tap.     Follow  manufacturer’s 
instruc  ons for installa  on and 
adjustment of the valves. 

• 

 The gas control valve on this water 
heater has been factory set to its 
lowest se   ng to reduce the risk 
of scalding. Higher temperatures 
increase the risk of scalding, but 
even at 120°F, hot water can scald. 
If you choose a higher tempera-
ture se   ng, Thermosta  c Mixing 
Valves located at each point-of-use 
are par  cularly important to help 
avoid scalding.

Table 1

Temperature

Time to Produce 
a Serious Burn

120°F (49°C)

More than 5 minutes

125°F (52°C)

1½ to 2 minutes

130°F (54°C)

About 30 seconds

135°F (57°C)

About 10 seconds

140°F (60°C)

Less than 5 seconds

145°F (63°C)

Less than 3 seconds

150°F (66°C)

About 1½ seconds

155°F (68°C)

About 1 second

 For  informa  on about changing the 
factory temperature se   ng, refer to 
the “Adjus  ng the Temperature” sec-

 on in this manual . 

Even if you set the water heater’s gas 
control valve to a low se   ng, higher 
water temperatures may occur in cer-
tain circumstances:

• 

 In some cases, repeated small draws 
of water can cause the hot and cold 
water in the tank to “stack” in layers. 
If this happens, the water can be as 
much as thirty degrees ho  er than 
the gas control valve se   ng. This 
temperature varia  on is the result 
of your usage pa  ern and is not a 
malfunc  on.

• 

 Water temperature will be ho  er if 
someone adjusted the gas control 
valve to a higher se   ng.

• 

 Problems with the gas control valve 
or other malfunc  ons may result in 
higher than expected water tem-
peratures.

• 

 If the water heater is in a hot envi-
ronment, the water in the tank can 
become as hot as the surrounding 
air, regardless of the temperature 
se   ng.

Содержание XCR-40-LP

Страница 1: ...on or service can damage the water heater your house and other property and present risks including fire scalding electric shock and explosion causing serious injury or death Do not store or use gasol...

Страница 2: ...t to cold water supply Hot water line T P relief valve Cold water shut o Dra hood T P discharge pipe Drain pan discharge pipe Metal drain pan Gas control valve thermostat Cold water line Gas supply sh...

Страница 3: ...uc ons is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of thi...

Страница 4: ...ake water hot enough to cause severe burns instantly resul ng in severe injury or death Feel water before bathing or showering To reduce the risk of scalding install Thermosta c Mixing Valves temperat...

Страница 5: ...on if you suspect flammable vapor have accumu lated inside or outside the appliance Immediately call a qualified person to inspect the appliance Water heaters subjected to a flammable vapors inci den...

Страница 6: ...odorless gas that is a by product of burning of fuels such as coal wood charcoal oil kerosene propane and natural gas Breathing excessive and abnormal amounts of carbon monoxide can cause carbon monox...

Страница 7: ...al plumbing supplier with compres sion fi ngs that don t require soldering This kit includes two 12 flex water lines two compression fi ngs an 18 flexible gas line two nipples and Teflon tape For home...

Страница 8: ...e you will need to conduct the vent dra test on pages 23 24 when installa on is finished If there is not enough ven la on you will need to ven late with outside air Check for Chemicals Installa ons wh...

Страница 9: ...or horizontal ducts B2 Determine type of ven la on There are several types of ven la on that can be used 1 Direct to outdoors 2 Ver cal ducts 3 Horizontal ducts 4 Single opening not recom mended must...

Страница 10: ...ension of no less than three inches All screens must have mesh or larger Moveable louvers must be locked open or interconnected with the equipment so that they open au toma cally during opera on Keep...

Страница 11: ...l spaces or any confined or inaccessible loca on Single wall vent pipe cannot pass through any interior wall Clearance to Combus ble Materials The vent pipe cannot pass through any ceiling floor firew...

Страница 12: ...m with type B double wall vent pipe Figure 9 Venting through a chimney with type B double wall vent pipe Gas Piping Gas piping must be installed accord ing to local and state codes or in the absence o...

Страница 13: ...at ing appliances when used to supply potable water Solar Installa on If this water heater is used as a solar stor age heater or as a backup for the solar system the water supply temperatures to the w...

Страница 14: ...s water pressure Locate your home s Pressure Reduc ing Valve PRV on the main incoming cold water supply line and adjust the water pressure control to between 50 and 60 psi If your home does not have...

Страница 15: ...eaks and can shut o the water heater s water supply if a leak occurs Install a metal drain pan available at your local plumbing supplier under the water heater to catch condensa on or leaks from the p...

Страница 16: ...If the water heater is installed di rectly on carpe ng it shall be in stalled on a metal or wood panel extending beyond the full width and depth of the water heater by at least 3 in 76 2mm in any dir...

Страница 17: ...flat blade screwdriver open the drain valve Sediment build up in the bo om of the water heater may hinder or prevent draining Figure 20 Draining the old water heater 8 Also open a hot water faucet to...

Страница 18: ...that extends beyond the dimen sions of the water heater width and depth by at least 3 inches 76 2 mm in any direc on If the water heater is installed on carpet in an alcove or closet the en re floor...

Страница 19: ...las c pipe or any type of hose Terminate the discharge pipe a maximum of six inches above a floor drain or outside the building Do not drain the discharge pipe into the drain pan instead pipe it separ...

Страница 20: ...g the water heater for service or replacement con nect the water pipes with a coupling called a union We recommend using a dielectric type union available at your local plumbing supplier Dielec tric u...

Страница 21: ...tor at the nearest hot water faucet This allows debris in plumbing system to be washed out of the pipes 2 Turn the cold water supply back on and fill the tank 3 Open a hot water faucet and allow the w...

Страница 22: ...ith large amounts of lint dust etc If so the air filter or flame arrestor located on the bo om of the water heater will need to be cleaned more o en Combus on Air Supply and Ven la on Adequate air sup...

Страница 23: ...three seconds Wait 10 minutes between ligh ng a empts 7 A solid Status Light means the pilot was lit but is now o Release the gas control knob and wait 10 minutes Once the Status Light goes out repea...

Страница 24: ...own as smelly water and can reduce the levels of bacteria that cause water borne diseases Water usage pa erns as well as heat from sources such as solar collectors ambient air and the pilot light can...

Страница 25: ...ot water is simply not warm enough there are several possible causes Faulty Thermosta c Mixing Valve in a faucet or shower control check other faucets in the house for hot water Water heater s capacit...

Страница 26: ...Valve or discharge pipe and do not operate the water heater without a func oning T P Relief Valve this could cause an explosion Water Pressure too High High water pressure can cause the T P Relief Va...

Страница 27: ...Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING...

Страница 28: ...the drain valve and place the other end of the hose in a drain outside or in buckets Note that sediment in the bo om of the tank may clog the valve and prevent it from draining If you can t get the t...

Страница 29: ...properly perform this visual inspec on or if the burner needs to be cleaned get help from a qualified person T P Relief Valve Maintenance Figure 45 T P Relief Valve Read and follow the opera ng and an...

Страница 30: ...d a 4 sec on of gas pipe into the inlet and use it to turn the FVIR Safety System Opera onal Checklist TROU BLESHOOTING CHART gas control valve thermostat counterclockwise Do not use pipe wrench or eq...

Страница 31: ...Residen al Standard Gas Water Heater Use and Care Guide 31 NOTES NOTES...

Страница 32: ...32 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 33: ...Residen al Standard Gas Water Heater Use and Care Guide 33 NOTES NOTES...

Страница 34: ...34 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 35: ...wire lead 11 OUTER DOOR 12 PILOT THERMOPILEASSEMBLY KIT 13 FINAL BURNER ASSEMBLY 14 MANIFOLD DOOR GASKET 15 BASE RING AIR FILTER REPAIR PARTS LIST 4 6 1 8 10 9 11 15 5 7 8 Replacement parts may be ord...

Страница 36: ...embly which contains the burner orifice manifold tube gasket door pilot tube thermopile manifold component block with retainer clip thermal switch and pilot assembly Natural Gas Low Nox or L P Item 14...

Отзывы: