background image

Residen  al Standard Gas Water Heater Use and Care Guide • 25

TR

OUBLE

SHOO

TING

Residen  al Standard Gas Water Heater Use and Care Guide • 25

TROUBLESHOOTING

keeps the tank from freezing during 
cold weather but can cause a Hydrogen 
gas build up. See cau  on on page 6. 

No Hot Water

Use the following step-by-step plan 
as a guide to help determine why you 
have no hot water: 

1

Check the Status Light

The Status Light on the gas 

control valve 

fl

 ashes once every three 

seconds if the pilot is lit and the gas 
control valve has not detected any 
problems. 

Figure 37 -

Status light.

If the Status Light is 

fl

 ashing once ev-

ery three seconds and you have no hot 
water, make sure the gas control knob 
is set to HOT. 
If the Status Light 

fl

 ashes more than 

once every three seconds, refer to 
the Status Light Code Troubleshoo  ng 
Chart on page 27.

If the Status Light is not 

fl

 ashing, go to 

step 2.

2

Status Light is Not 
Flashing

If the Status Light isn’t 

fl

 ashing, try 

ligh  ng the pilot using the ligh  ng 
instruc  ons on page 23.

If you have tried ligh  ng the pilot and the 
Status Light does not 

fl

 ash, go to step 3.

If the Status Light 

fl

 ashes, go to Step 1.

3

Checking the Pilot Light

Check the spark igniter. Dim 

the room lights and look through the 
viewport while clicking the igniter 
bu  on. 

If you don’t see a spark through the 
viewport, check to make sure the 
igniter wire is 

fi

 rmly inserted into the 

white connector. 

If you see a spark, make sure the gas 
supply valve is turned on, and try light-
ing the pilot using the ligh  ng instruc-

 ons on page 23. 

If the pilot s  ll does not light, call a 
quali

fi

 ed person.

Insu

  cient Hot Water 

or Slow Hot Water
Recovery

WARNING! Because of the increased 

risk from scalding, if you set the water 
heater’s gas control knob higher than 
120°F, install Thermosta  c Mixing 
Valves at each point-of-use. Due to the 
increased risk of scalding, do not set the 
temperature of the Thermosta  c 
Mixing Valves above 120°F.

If the hot water is simply not warm 
enough, there are several possible 
causes:

•  

Faulty 

Thermosta  c Mixing Valve 

in a faucet or shower control 
(check other faucets in the house 
for hot water).

• 

 Water heater’s capacity too small 
(or usage too high).

• 

 Reversed plumbing connec  ons 
or melted dip tube (usually found 
soon a  er new installa  on).

• Plumbing 

leak.

• 

 Sediment or lime build up in the 
bo  om of the tank.

Thermosta  c Mixing Valves.

 If the 

hot water is simply not warm enough, 
make sure the faucet you are checking 
doesn’t have a defec  ve Thermosta  c 
Mixing Valve. Many shower controls 
now have built-in mixing valves. If 
these devices fail, they can reduce the 
amount of hot water the shower or 
faucet delivers even though there is 
plenty of hot water in the tank. Always 
check the water temperature at several 
faucets to make sure the problem is not 
in a faucet or shower control.

Undersized Water Heater. 

If your water 

heater runs out of hot water quickly, it 
may be too small for your needs. If the 
water heater is old, consider replacing it 
with a larger model. If the water heater 
is in good condi  on, you may be able 
to meet your family’s hot water needs 
with the exis  ng water heater by install-
ing Thermosta  c Mixing Valves at each 
point-of-use and then turning the gas 
control knob to a higher se   ng.

You can also reduce your home’s hot 
water needs by washing clothes in cold 
water, installing 

fl

 ow restrictors on 

shower heads, repairing leaky faucets, 
and taking other conserva  on steps. 

Reversed Connec  ons or Melted Dip 
Tube.

 Check the hot and cold water 

connec  ons and make sure your 
home’s hot water pipe is connected 
to the hot water outlet on the water 
heater. Usually, reversed connec  ons 
are found soon a  er the installa  on 
of a new unit. If copper pipes were 
soldered while they were a  ached to 
the water heater, the dip tube may 
have melted. The dip tube is a long, 
plas  c tube inside the tank a  ached to 
the cold water inlet. If the dip tube has 
melted, it can be replaced by removing 
the cold water inlet connec  on, re-
moving the old dip tube and installing 
a new one.  

Plumbing Leak. 

Even a small leak 

in the hot water side of the home’s 

Содержание XCR-40-LP

Страница 1: ...on or service can damage the water heater your house and other property and present risks including fire scalding electric shock and explosion causing serious injury or death Do not store or use gasol...

Страница 2: ...t to cold water supply Hot water line T P relief valve Cold water shut o Dra hood T P discharge pipe Drain pan discharge pipe Metal drain pan Gas control valve thermostat Cold water line Gas supply sh...

Страница 3: ...uc ons is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of thi...

Страница 4: ...ake water hot enough to cause severe burns instantly resul ng in severe injury or death Feel water before bathing or showering To reduce the risk of scalding install Thermosta c Mixing Valves temperat...

Страница 5: ...on if you suspect flammable vapor have accumu lated inside or outside the appliance Immediately call a qualified person to inspect the appliance Water heaters subjected to a flammable vapors inci den...

Страница 6: ...odorless gas that is a by product of burning of fuels such as coal wood charcoal oil kerosene propane and natural gas Breathing excessive and abnormal amounts of carbon monoxide can cause carbon monox...

Страница 7: ...al plumbing supplier with compres sion fi ngs that don t require soldering This kit includes two 12 flex water lines two compression fi ngs an 18 flexible gas line two nipples and Teflon tape For home...

Страница 8: ...e you will need to conduct the vent dra test on pages 23 24 when installa on is finished If there is not enough ven la on you will need to ven late with outside air Check for Chemicals Installa ons wh...

Страница 9: ...or horizontal ducts B2 Determine type of ven la on There are several types of ven la on that can be used 1 Direct to outdoors 2 Ver cal ducts 3 Horizontal ducts 4 Single opening not recom mended must...

Страница 10: ...ension of no less than three inches All screens must have mesh or larger Moveable louvers must be locked open or interconnected with the equipment so that they open au toma cally during opera on Keep...

Страница 11: ...l spaces or any confined or inaccessible loca on Single wall vent pipe cannot pass through any interior wall Clearance to Combus ble Materials The vent pipe cannot pass through any ceiling floor firew...

Страница 12: ...m with type B double wall vent pipe Figure 9 Venting through a chimney with type B double wall vent pipe Gas Piping Gas piping must be installed accord ing to local and state codes or in the absence o...

Страница 13: ...at ing appliances when used to supply potable water Solar Installa on If this water heater is used as a solar stor age heater or as a backup for the solar system the water supply temperatures to the w...

Страница 14: ...s water pressure Locate your home s Pressure Reduc ing Valve PRV on the main incoming cold water supply line and adjust the water pressure control to between 50 and 60 psi If your home does not have...

Страница 15: ...eaks and can shut o the water heater s water supply if a leak occurs Install a metal drain pan available at your local plumbing supplier under the water heater to catch condensa on or leaks from the p...

Страница 16: ...If the water heater is installed di rectly on carpe ng it shall be in stalled on a metal or wood panel extending beyond the full width and depth of the water heater by at least 3 in 76 2mm in any dir...

Страница 17: ...flat blade screwdriver open the drain valve Sediment build up in the bo om of the water heater may hinder or prevent draining Figure 20 Draining the old water heater 8 Also open a hot water faucet to...

Страница 18: ...that extends beyond the dimen sions of the water heater width and depth by at least 3 inches 76 2 mm in any direc on If the water heater is installed on carpet in an alcove or closet the en re floor...

Страница 19: ...las c pipe or any type of hose Terminate the discharge pipe a maximum of six inches above a floor drain or outside the building Do not drain the discharge pipe into the drain pan instead pipe it separ...

Страница 20: ...g the water heater for service or replacement con nect the water pipes with a coupling called a union We recommend using a dielectric type union available at your local plumbing supplier Dielec tric u...

Страница 21: ...tor at the nearest hot water faucet This allows debris in plumbing system to be washed out of the pipes 2 Turn the cold water supply back on and fill the tank 3 Open a hot water faucet and allow the w...

Страница 22: ...ith large amounts of lint dust etc If so the air filter or flame arrestor located on the bo om of the water heater will need to be cleaned more o en Combus on Air Supply and Ven la on Adequate air sup...

Страница 23: ...three seconds Wait 10 minutes between ligh ng a empts 7 A solid Status Light means the pilot was lit but is now o Release the gas control knob and wait 10 minutes Once the Status Light goes out repea...

Страница 24: ...own as smelly water and can reduce the levels of bacteria that cause water borne diseases Water usage pa erns as well as heat from sources such as solar collectors ambient air and the pilot light can...

Страница 25: ...ot water is simply not warm enough there are several possible causes Faulty Thermosta c Mixing Valve in a faucet or shower control check other faucets in the house for hot water Water heater s capacit...

Страница 26: ...Valve or discharge pipe and do not operate the water heater without a func oning T P Relief Valve this could cause an explosion Water Pressure too High High water pressure can cause the T P Relief Va...

Страница 27: ...Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING Residen al Standard Gas Water Heater Use and Care Guide 27 TROUBLESHOOTING...

Страница 28: ...the drain valve and place the other end of the hose in a drain outside or in buckets Note that sediment in the bo om of the tank may clog the valve and prevent it from draining If you can t get the t...

Страница 29: ...properly perform this visual inspec on or if the burner needs to be cleaned get help from a qualified person T P Relief Valve Maintenance Figure 45 T P Relief Valve Read and follow the opera ng and an...

Страница 30: ...d a 4 sec on of gas pipe into the inlet and use it to turn the FVIR Safety System Opera onal Checklist TROU BLESHOOTING CHART gas control valve thermostat counterclockwise Do not use pipe wrench or eq...

Страница 31: ...Residen al Standard Gas Water Heater Use and Care Guide 31 NOTES NOTES...

Страница 32: ...32 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 33: ...Residen al Standard Gas Water Heater Use and Care Guide 33 NOTES NOTES...

Страница 34: ...34 Residen al Standard Gas Water Heater Use and Care Guide NOTES NOTES...

Страница 35: ...wire lead 11 OUTER DOOR 12 PILOT THERMOPILEASSEMBLY KIT 13 FINAL BURNER ASSEMBLY 14 MANIFOLD DOOR GASKET 15 BASE RING AIR FILTER REPAIR PARTS LIST 4 6 1 8 10 9 11 15 5 7 8 Replacement parts may be ord...

Страница 36: ...embly which contains the burner orifice manifold tube gasket door pilot tube thermopile manifold component block with retainer clip thermal switch and pilot assembly Natural Gas Low Nox or L P Item 14...

Отзывы: