General Safety (cont’d)

3

WARNING

This water heater must not be installed directly on carpeting. Car-

peting must be protected by a metal or wood panel beneath the

appliance extending beyond the full width and depth of the ap-

pliance by at least 3 inches (76.2mm) in any direction, or if the ap-

pliance is installed in an alcove or closet, the entire floor must be

covered by the panel. Failure to heed this warning may result in a

fire hazard.

WARNING

A gas water heater cannot operate properly without the correct

amount of air for combustion. Do not install in a confined area such

as a closet, unless you provide air as shown in the “Locating The

New Water Heater” section. Never obstruct the flow of ventilation

air. If you have any doubts or questions at all, call your gas com-

pany. Failure to provide the proper amount of combustion air can

result in a fire or explosion and can cause DEATH, SERIOUS BOD-

ILY INJURY, OR PROPERTY DAMAGE.

WARNING

If this water heater will be used in beauty shops, barber shops,

cleaning establishments, or self-service laundries with dry cleaning

equipment, it is imperative that the water heater or water heaters be

installed so that combustion and ventilation air be taken from out-

side these areas. Refer to the “Locating The New Water Heater”

section of this manual and also the current edition of the National

Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for

specifics provided concerning air required.

WARNING

The power vent water heater requires its own (separate) venting

system. It cannot be connected to  an existing vent pipe or chim-

ney. It must be terminated to the outdoors. Failure to properly in-

stall the venting system can result in asphyxiation, a fire or explo-

sion and can cause DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.

WARNING

No vent damper installation is compatible with this power vented

water heater design. No vent damper, whether it is operated ther-

mally or otherwise is to be installed on this power vented water

heater. Alteration of any part of the factory-furnished vent assembly

could result in improper operation due to restriction of flue gases,

spillage of flue gases and may cause carbon monoxide poisoning.

WARNING

1. The appliance and its individual shutoff valve must be discon-

nected from the gas supply piping system during any pressure

testing of the gas system at test pressures in excess of 

1

2

pound

per square inch (3.5kPa).

2. The appliance must be isolated from the gas supply piping sys-

tem by closing its individual manual shutoff valve during any

pressure testing of the gas supply piping system at test pres-

sures equal or less than 

1

2

pound per square inch (3.5kPa).

WARNING

Soot build-up indicates a problem that requires correction before

further use. Turn “off” gas to water heater and leave “off” until re-

pairs are made, because failure to correct the cause of the sooting

can result in a fire or explosion causing DEATH, SERIOUS BODILY

INJURY, OR PROPERTY DAMAGE.

WARNING

The water heater with vent pipe installed must be properly vented

outdoors. Never operate the water heater unless it is vented to the

outdoors and has adequate air supply to avoid risks of improper

operation, explosion or asphyxiation.

WARNING

Vent termination must not be within 4 feet of any items such as gas

meters, gas valves or other gas regulating equipment.

WARNING

Obstructed or deteriorated vent systems may present a serious

health risk or asphyxiation.

WARNING

Chemical vapor corrosion of the flue and vent system may occur if

air for combustion contains certain chemical vapors. Spray can pro-

pellants, cleaning solvents, refrigerator and air conditioner refrig-

erants, swimming pool chemicals, calcium and sodium chloride,

waxes, bleach, and process chemicals are typical compounds which

are potentially corrosive.

WARNING

Minimum clearances between the water heater and combustible

and non-combustible construction are: 0 inches from sides, 0 inch-

es from back, 5 inches from front of jacket to closet door and 14

inches from top of jacket to combustible and non-combustible

material. Minimum vent clearance: 0 inches. Provide 24 inches

front clearance for servicing and adequate clearance between the

jacket top & ceiling for servicing the flue area. 

WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water

system that has not been used for a long period of time (generally

two weeks or more). Hydrogen gas is extremely flammable and

explosive. To prevent the possibility of injury under these condi-

tions, we recommend the hot water faucet be opened for several

minutes at the kitchen sink before any electrical appliances which

are connected to the hot water system are used (such as a dish-

washer or washing machine). If hydrogen gas is present, there will

probably be an unusual sound similar to air escaping through the

pipe as the hot water faucet is opened. There must be no smoking or

open flame near the faucet at the time it is open.

WARNING

INSULATING JACKETS: When installing an external water heater

insulation jacket on a gas water heater:

a. DO NOT cover the temperature-pressure relief valve.

b. DO NOT put insulation over any part of the top of the gas water

heater.

c. DO NOT put insulation over the gas control valve or gas con-

trol valve/burner cover, or any access areas to the burner.

d. DO NOT let insulation around the gas water heater to get with-

in 8 inches of the floor (air must get to the burner).

e. DO NOT remove operating instructions, and safety related warn-

ing labels and materials affixed to the water heater. DO obtain

new warning and instruction labels from the manufacturer for

placement on the jacket directly over the existing labels.

Failure to heed this will result in the possibility of a fire or explosion.

WARNING

Flood damage to a water heater may not be readily visible or imme-

diately detectible. However, over a period of time a flooded water

heater will create dangerous conditions which can cause DEATH,

SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Call a qual-

ified service technician or contractor to replace a flooded water

heater. Do not attempt to repair the unit! It must be replaced!

CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water

heater must be accomplished in such a manner that if the tank or

any connections should leak, the flow of water will not cause dam-

age to the structure. For this reason, it is not advisable to install the

water heater in an attic or upper floor. When such locations cannot

be avoided, a suitable drain pan should be installed under the water

heater. Drain pans are available at your local hardware store. Such

a drain pan must be not greater than 1

1

2

inches deep, have a mini-

mum length and width of at least 2 inches greater than the water

heater dimensions and must be piped to an adequate drain. The pan

must not restrict combustion air flow.

Содержание Residential Power Vent Gas Water Heaters with Hot Surface...

Страница 1: ...s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the info...

Страница 2: ...r is detected follow steps indicated at For Your Safety on the cover page of this manual then leave the premises WARNING Improper installation adjustment alteration service or main tenance can cause d...

Страница 3: ...as regulating equipment WARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation WARNING Chemical vapor corrosion of the flue and vent system may occur if air...

Страница 4: ...2 Gas Piping 22 23 Installation Checklist 24 Operating 25 27 Temperature Regulation 28 For Your Information 29 30 Start Up Conditions 29 Condensation 29 Smoke Odor 29 Thermal Expansion 29 Strange Soun...

Страница 5: ...operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation and maintenance of the gas fired water heater It als...

Страница 6: ...RGE PIPE Do not cap or plug PROVIDE A 6 AIR GAP BETWEEN THE END OF THE DISCHARGE PIPE AND DRAIN 7 power cord Factory supplied Some models are equipped with circulating loop fittings WARNING This water...

Страница 7: ...ions cannot be avoided a suitable drain pan should be installed under the water heater Drain pans are available at your local hardware store Such a drain pan must be not greater than 11 2 inches deep...

Страница 8: ...7 Y 3 1 LgN N LgV 1 g XgN J H N L 1g 3 3 L 1g N Lg 1g 3 7 5 3 1 e L f V N 1 h3 X f L f N J H N e3 1 gN L L gN 1 f 1 g3 7 L eV Lg 3 3 1 Xg 3 Lf LgN 5 3 1 e N X f N N 1g N X e H V 1g 3 J H N f3 1 g3 3...

Страница 9: ...r servicing and proper operation of the water heater Figure 4 The venting system must be installed in a manner which allows inspection of the installation of the venting pipes and joints as well as pe...

Страница 10: ...total input rating of all equipment in the enclosure See Figure 9 4 When ducts are used they shall be of the same cross sec tional area as the free area of the openings to which they connect The mini...

Страница 11: ...apter to the cold water inlet con nection Do not solder the cold water supply line directly to the cold water inlet or it will harm the dip tube NOTE This water heater is insulated to minimize heat lo...

Страница 12: ...art The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet or use of more than four elbows can cause restriction and reduce the discharge ca...

Страница 13: ...ters junction box 7 MAXIMUM CORD LENGTH Factory supplied You must provide all wiring of the proper size outside of the water heater You must obey local codes and electric company requirements when you...

Страница 14: ...n box Connect ground wire to this location For complete grounding details and all allowable exceptions refer to local codes or in the absence of local codes with the National Electrical Code ANSI NFPA...

Страница 15: ...er heater the correct vent pipe diameter must be utilized Do not install any other gas appliances on the same vent with this water heater as this will adversely affect the operation of the water heate...

Страница 16: ...VC ABS or CPVC Schedule 40 reducer must be supplied locally 5 A 4 PVC ABS or CPVC Schedule 40 90 street ell used to connect the vent pipe to the reducer when the vent pipe is to be turned horizontally...

Страница 17: ...CPVC Schedule 40 reducer must be supplied locally 5 A 2 PVC ABS or CPVC Schedule 40 90 street ell used to connect the vent pipe to the reducer when the vent pipe is to be turned horizontally off the...

Страница 18: ...AX LENGTH FT 90 ELBOWS 70 1 65 2 60 3 55 4 50 5 45 6 ALL 40 and 50 GALLON 40 000 BTU HR MODELS ONLY 3 DIA VENT NUMBER OF MAX LENGTH FT 90 ELBOWS 115 1 110 2 105 3 100 4 95 5 90 6 ALL 40 and 50 GALLON...

Страница 19: ...e them near heat sparks or flames Keep containers closed Use them in well ventilated areas Wear impervious clothing while handling Do not smoke eat or drink while handling Wash thoroughly after handli...

Страница 20: ...E When determining location of the opening in the outside wall allow for the 1 8 rise per five feet that has taken place in the horizontal run MIN RISE 1 8 PER FIVE FEET C L OF FLUE 40 GAL 60 50 GAL 5...

Страница 21: ...3 TO 2 PVC ABS OR CPVC REDUCER 4 If the optional 4 vent piping is to be used 50 000 BTU Hr and higher models only the 4 street elbow 4 to 3 reducer and 3 minimum section of 3 PVC ABS or CPVC pipe mus...

Страница 22: ...EARANCE EXHAUST VERTICAL VENT CERTIFIED WATER HEATER TOTAL VERTICAL AND HORIZONTAL RUNS SEE ITEM 6 45 VENT CAP 90 STREET ELL 6 The total vertical and horizontal vent run cannot exceed the maximum leng...

Страница 23: ...VALVE GROUND JOINT UNION BLACK PIPE DRIP LEG SEDIMENT TRAP CAP 3 MIN 3 MIN A gas line of sufficient size must be run to the water heater Consult the current edition of National Fuel Gas Code ANSI Z223...

Страница 24: ...r heater completely filled with water See Filling the Water Heater instructions in the Installing the New Water Heater section 5 Will a water leak damage anything See the Locating the New Water Heater...

Страница 25: ...mation section 4 There is a non resettable hi limit switch in the thermo stat which must be good closed for the thermostat to be operated See High Temperature Shut Off System in the For Your Informati...

Страница 26: ...s by sniffing at ground level in the vicinity of the appliance If odor is detected follow the steps indicated at For Your Safety on the cover page of this manual then leave the premises WARNING AN ODO...

Страница 27: ...essing the COOLER and HOTTER buttons together and holding for 1 second Then press the COOLER button until the WARM indicator light appears 2 Set the ON OFF switch on the control box to the OFF positio...

Страница 28: ...you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs some type of tempering device such as a mixing valve should be used...

Страница 29: ...hermal expansion and closed systems do not allow for the expan sion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the...

Страница 30: ...ormation cont d SMELLY WATER cont d If the smelly water persists after the anode replacement and chlorination treatment we can only suggest that continuous chlorination and filtering conditioning equi...

Страница 31: ...calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive WARNING Obstructions and deteriorated vent systems may present serious health risk...

Страница 32: ...ay be due to thermal expansion Your water heater may have a check valve installed in the water line or a water meter with a check valve Consult the water supplier and or plumbing contractor for furthe...

Страница 33: ...drain valve should be left open with hose connected allowing water to ter minate to an adequate drain 6 Close the drain valve 7 Follow instructions in the Filling The Water Heater section 8 Follow the...

Страница 34: ...This is common at the time of startup after installation and when incoming water is cold Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve...

Страница 35: ...roper and possible danger ous operation resulting in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE THERMOSTAT AND GAS SUPPLY CHECK Is thermostat calling for heat Run hot water from heater and set adj...

Страница 36: ...intake or exhaust obstructed Error in the hot surface ignitor circuit 1 Check that all wiring is correct and secure 2 Replace hot surface ignitor System in lockout 1 Gas supply is off or too low to o...

Страница 37: ...st venting and YELLOW FLAME air openings in bottom base pan for obstructions or blockage C Not enough dilution air for proper Check dilution air intake for obstructions or combustion blockage A Water...

Страница 38: ...Parts 1 2 3 4 5 7 8 9 10 11 21 12 14 13 15 17 16 23 22 20 24 25 26 27 28 29 30 18 19 6 PVC ABS or CPVC items for all models supplied locally or OR 8 9 Blower Draft Hood Assembly for 40 000 Btu Hr Mod...

Страница 39: ...from or the manufacturer listed on the model rating plate on the water heater Be sure to provide all pertinent facts when you call or visit Selling prices will be furnished on request or parts will b...

Страница 40: ......

Отзывы: