25
INTAKE AIR CONNECTION
INTAKE AIR CONNECTION
The intake air connection has a screen and a hose barb installed at the factory, see Figure below.
The intake air connection screen is installed to prevent debris from entering the Combustion Blower and/or Burner. This screen is left in
place when the water heater is installed in a Power Vent configuration but must be removed before connecting the intake air piping on
Direct Vent installations. Once the intake air pipe is installed the screen, if not removed, would be hidden from view and may become
clogged with debris over time. This can cause poor combustion and
Blocked Air Intake
fault conditions and Control System lock outs.
Ensure this screen has been removed on all Direct Vent installations if experiencing
Blocked Air Intake
fault conditions.
Six-Inch Coupling - Factory Installed
Intake Air Screen
(Remove for Direct Vent)
Blocked Air Intake
Pressure Port
Firere 18. AIR INTAKE SCREEN
Service Notes:
•
Plastic debris left on the edges of intake air pipe sections after cutting must be removed on Direct Vent installations. This debris can
collect inside and clog the Burner which can cause poor combustion, sooting, rough starting, rough operation and
Ignition Failure
fault conditions and Control System lock outs. The Burner is a radial design that can trap debris. See
.
•
Exceeding the equivalent length limitations for the vent piping will cause
Blocked Exhaust
fault conditions and Control System lock
outs.
•
Exceeding the equivalent length limitations for the intake air piping will cause
Blocked Air Intake
fault conditions and Control System
lock outs.
•
Exceeding the maximum number of elbows allowed for the intake air and/or vent piping will also cause
Blocked Air Intake
and
Blocked Exhaust
fault conditions and Control System lock outs.
•
Using smaller intake air and/or vent pipe than required for the installed equivalent length will also cause
Blocked Air Intake
and
Blocked Exhaust
fault conditions and Control System lock outs.
Содержание Cyclone XL 100 Series
Страница 41: ...41 NOTES NOTES...
Страница 42: ...42 NOTES NOTES...
Страница 43: ...43 NOTES NOTES...
Страница 44: ...44 Tech Support 800 527 1953 Parts 800 433 2545 www hotwater com Copyright 2020 All rights reserved...