30
BLOWER SPEED CONTROL
BLOWER SPEED CONTROL
The CCB monitors a feedback signal from a sensor that is installed on the blower. The CCB interprets the pulse signal from the sensor
and then sends a signal to the blower to produce the proper blower speed and input.
These models are capable of modulating their input rate. Therefore, the RPM readings can be in between the Heating Speed and
Minimum Modulation Speed RPMs. The input rate should be verified with the water heater operating at full input rate.
list the RPMs
for each model at high heating speed, low fire speed, and ignition speed.
Table 2. Blower RPMs - Nateral Gas
Nateral Gas
Hirh Heatinr Speed - RPM
Low Fire Speed RPM
Irnition Speed RPM
BTHS 750
4475
2300
2000
BTHS 1000
6000
2300
2000
* Note: ±10% High Heating Speed RPMs are based from the Nominal “Certification” Heating Speed RPMs.
Table 3. Blower RPMs - Propane Gas
Propane Gas
Hirh Heatinr Speed - RPM
Low Fire Speed RPM
Irnition Speed RPM
BTHS 750
4350
2700
2000
BTHS 1000
5800
2700
2000
* Note: ±10% High Heating Speed RPMs are based from the Nominal “Certification” Heating Speed RPMs.
BURNER ASSEMBLY
BURNER ASSEMBLY
The Burner is a radial design burner with a steel fiber jacket on the outer surface and is part of a larger Burner Assembly. Figures below
show side views of the complete Burner Assembly removed from the water heater with key components identified. See the exploded
view in
Flame rod, ½” to
burner surface
Spark igniter,
0.125” spark gap,
~1/2” to burner
surface
Firere 20. Berner Assembly