38
CPAM – COMMERCIAL POWER ANODE MODULE
The CPAM, which is mounted on the control panel backplate behind the UIM, provides catholic protection to the water heater tank
through the two front-side mounted power anodes. The CPAM module will communicate with the CCB for its current, voltages. CPAM
faults will be monitored by the CCB which will issue a fault for the powered anode circuit and will be displayed on the UIM.
Table 18. CPAM Faelt & Warninr Codes & Corrective Action
Code
Description
Corrective Action
Cc
Anode Shorted
Check wiring for shorts, clean anode
Ce
Hardware fail (ADC error)
Reset power, if still fails replace CCB or CPAM.
D1
Hardware fail (Over current)
Reset power, if still fails replace CCB or CPAM.
D4
Hardware fail (Drive voltage LT tank)
Reset power, if still fails replace CCB or CPAM.
D6
Anode Open/No Water
Check if water in tank, Check wiring to be connected to anode
D8
Hardware fail (No current sense)
Reset power, if still fails replace CCB or CPAM.
D9
Anode shorted
Check wiring for shorts, clean anode