background image

23

Limited Warranty

A. O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater.

1.

THE TANK

If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water
therein, during the first THREE years after initial installation, the warrantor will supply a complete new A. O. Smith water heater of equivalent size and
current model.  Some government agencies are requiring energy efficient standards for water heaters.  In the event regulations prohibit sale of a
model of equivalent size and construction, A. O. Smith will provide a model which complies with the regulations of your area, in which case the
consumer will be charged the difference in price between the like replacement and the energy efficient model required.  The warranty on the
replacement water heater will be limited to the unexpired term of the original warranty.

2.

ALL OTHER PARTS

If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in
material or workmanship, the warrantor will repair or replace such part or portion at its option.

3.

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations,
the printed instructions provided with it and good industry practices.  In addition, a temperature and pressure relief valve, certified by and officially
sanctioned and recognized independent testing agency and approved by the American Society of Mechanical Engineers, must have been installed.
a.       This warranty shall apply only when the heater is:

(1)

used at temperatures not exceeding the maximum calibrated setting of its thermostat;

(2)

used at water pressure not exceeding the working pressure shown on the heater;

(3)

filled with potable water, free to circulate at all times and with the tank free of damaging water sediment or scale deposits;

(4)

used in a non-corrosive and non-contaminated atmosphere;

(5)

used with factory approved anode(s) installed;

(6)

 in its original installation location;

(7)

 in the United States, its territories or possessions;

(8)

sized in accordance with proper sizing techniques for commercial and/or residential water heaters;

(9)

bearing a rating plate which has not been altered, defaced or removed, except as required by the warrantor;

(10)

used in an open system or in a closed system with properly sized and installed thermal expansion tank;

(11)

operated with properly installed dirt leg;

(12)

fired with the fuel for which it was factory built;

(13)

fired at the factory rated input;

(14)

operated with the inner and outer combustion chamber doors in place.

b.

Any accident to the water heater, any misuse, abuse (including freezing or thermal expansion damage) or alteration of, any operation in a
modified form, or any attempt to repair tank leaks will void this warranty.

c.

This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is
connected to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times.  The relief
valve installed on the heater is not an acceptable method.

4.

SERVICE AND REPAIR EXPENSES

Under the limited warranty the warrantor will provide only a replacement water heater or part thereof.  The owner is responsible for all other costs.

Such costs may include but are not limited to:
a.

Labor charges for service removal, repair or reinstallation of the water heater or any component part;

b.

Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and
returning the claimed defective heater or part to such distributor.

c.

All cost necessary or incidental for any material and/or permits required for installation of the replacement heater or part.

5.

LIMITATIONS ON IMPLIED WARRANTIES

Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration for
the heater or any of its parts.  Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.

6.

CLAIM PROCEDURE

Any claim under the warranty should be initiated with the dealer who sold the heater, or with any other dealer handling the warrantor’s products.  If this
is not practicable, the owner should contact:

U.S. Customers
A. O. Smith Water Products Company
500 Tennessee Waltz Parkway
Ashland City, TN 37015
Telephone: (800) 323-2636

a.

The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the

warrantor.

b.

Dealer replacements are made subject to in-warranty validation by warrantor.

7.

DISCLAIMERS

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANT-
ABILITY OF THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE HEATER.  THE WARRANTOR SHALL
NOT BE RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROP-
ERTY OR OTHER CONSEQUENTIAL DAMAGE.  THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHER-
WISE FOR DAMAGE TO ANY PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR IN
TORT.
a.

Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not
apply to you.

b.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Fill in the following for your own reference.  Keep it. Registration is not a condition of warranty.  The model and serial number are found on the heater’s
rating plate.
Model No. ____________________Serial No. _____________________________________________Date Installed__________________________

Dealer’s Name____________________________________________________________________________________________________________

Dealer’s Address ________________________________________________________________________ Phone No.________________________

City and State __________________________________________________________________________  Zip _____________________________

KEEP THIS WARRANTY POSTED ADJACENT TO THE HEATER FOR FUTURE REFERENCE.

Содержание BTX-80

Страница 1: ...TAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE MODEL BTX 80 COMMERCIAL GAS WATER HEATER Glass Lined Tank Type Water Heater GET TO KNOW YOUR...

Страница 2: ...0 50 189 Nat 4 00 0 99 120 60 5 All models Maximum Supply Pressure 14 inches W C 3 48kPa Minimum Supply Pressure Natural Gas 5 0 inches W C 1 24kPa Minimum Pressure must be maintained under both load...

Страница 3: ...of part numbers and descriptions Standard hardware items may be purchased locally A VENT PIPE B ANODE C HOT WATER OUTLET D OUTLET 120 VAC F GAS SUPPLY G MAIN MANUAL GAS SHUT OFF VALVE H GROUND JOINT...

Страница 4: ...suspected do not attempt to find the cause yourself Go to a neighbor s house leaving your doors open to ventilate the house then call your gas supplier or service agent Keep area clear until a servic...

Страница 5: ...arance of 24 should be allowed for blower assembly service Adequate clearance for servicing this appliance should be considered before installation such as changing the anodes etc Minimum clearances f...

Страница 6: ...or component s previously used with a non potable water heating appliance 4 When the system requires water for space heating at temperatures higher than required for domestic water purposes a temperi...

Страница 7: ...er heater With main burner in operation paint pipe joints including flanges and control inlet and outlet with rich soap and water solution Bubbles indicate gas leak To stop leak tighten flange screws...

Страница 8: ...pling or other restriction and must terminate near a suitable drain to prevent water damage during valve operation The discharge line shall be installed in a manner to allow complete drainage of both...

Страница 9: ...ng PVC Materials should useASTM D 2564 Grade Cement CPVC Materials should use ASTM F 493 Grade Cement and ABS Materials should use ASTM D 2235 Grade Cement If the water heater is being installed as a...

Страница 10: ...lued into the end of the elbow that will mount on the discharge boot INSTALLATION OF VENT SYSTEM Before beginning installation of piping system thoroughly read the section of this manual VENT PIPE PRE...

Страница 11: ...AUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING POWER VENT WIRING SCHEMATIC FIGUR...

Страница 12: ...ION INSTALLATION OF VERTICAL VENT SYSTEM A proper flashing or BOOT should be used to seal the pipe where it exits the roof The total vent system should not exceed the equivalent feet of pipe as listed...

Страница 13: ...ir tight to prevent any combustion gases escaping into the room If the plug is not securely tightened remove and reinstall using Teflon tape on the threads Once installed along with the rest of the ve...

Страница 14: ...leaks will allow flue gas by products to disseminate into the room creating an unsafe environment and could cause illness asphyxiation and or even death FIGURE 12 Typical Installation for Vertical Ven...

Страница 15: ...0 pipe Never use all purpose cements commercial glues and adhesives or ABS cement to join PVC or CPVC pipe and fittings SAFETY PRECAUTION PRIMERS AND CEMENTS ARE EXTREMELY FLAMMABLE AND MUST NOT BE ST...

Страница 16: ...after it has hit the bottom of the fitting socket A good joint will have sufficient cement to make a bead all the way around the outside of the fitting hub The fitting will have a tendency to slide b...

Страница 17: ...PERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to ligh...

Страница 18: ...E ACCESS It is recommended that lower water temperatures be used to avoid the risk of scalding It is further recommended in all cases that the water temperature be set for the lowest temperature which...

Страница 19: ...k in operating condition SERVICE SHOULD BE PERFORMED ONLY BY A QUALIFIED SERVICE TECHNICIAN READ THE GENERAL SAFETY INFORMATION SECTION FIRST USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENT...

Страница 20: ...r writing to us at A O Smith Water Products Company Service Department 500 Tennessee Waltz Parkway Ashland City TN 37015 1299 or going to our website at www hotwater com Please click on Contact us the...

Страница 21: ...afety water heater service should be performed only by a qualified service technician Read the GENERAL SAFETY INFORMATION section first WARNING DO NOT BY PASS ANY CONTROLS TO MAKE HEATER OPERATE OPERA...

Страница 22: ...cuit 1 Turn power to the water heater off for 10 seconds and then back on 2 Replace gas control valve Problem with the internal circuit 1 Turn power to the water heater off for 10 seconds and then bac...

Страница 23: ...nless an effective method of controlling thermal expansion is also installed at the heater s and operational at all times The relief valve installed on the heater is not an acceptable method 4 SERVICE...

Страница 24: ...24...

Отзывы: