Installation
30
Instruction manual ADMR
3
is
3.10.2
Preparation
Caution
The appliance is phase-sensitive. It is
absolutely essential
to connect the
mains phase (L) to the phase of the appliance, and the mains neutral (N) to the
neutral of the appliance.
Caution
There may be
no potential difference
between neutral (N) and earth ( ).
If this is the case, then an isolating transformer must be applied in the supply
circuit (3.10.5 "Connecting an isolating transformer").
For more information or to order this isolating transformer, please contact
A.O. Smith Water Products Company.
The figure shows a view of the terminal blocks, and the table explains the
relevant connections.
Terminal blocks
In preparation you must first remove the protective cover from the control
1. Undo the 4 screws (A) and remove the protective cover (B) from the
electrical section. The terminal blocks (C) will now be visible.
Consult the Electrical Diagrams ADMR for the electrical component
connections.
Legend
A. screws
B. protective cap
C. connector block
31
19
13
30
18
1
A
C
B
12
36
IMD-0125 R2
Содержание ADMR - 40
Страница 4: ...4 Instruction manual ADMR gis ...
Страница 10: ...Introduction 10 Instruction manual ADMR 1 gis ...
Страница 54: ...Shutting down 54 Instruction manual ADMR 10 gis ...
Страница 62: ...Main menu 62 Instruction manual ADMR 11 gis ...
Страница 76: ...is Instruction manual ADMR 76 ...
Страница 78: ...Maintenance frequency 78 Instruction manual ADMR 14 is ...
Страница 84: ...Performing maintenance 84 Instruction manual ADMR 15 s ...
Страница 92: ...Appendices 92 Instruction manual ADMR 17 is ...
Страница 94: ...Instruction manual ADMR 94 ...