57
LEAKAGE CHECKPOINTS
LEAKAGE CHECKPOINTS
B: Anode Rod
Connection
A: Inlet &
Outlet
K: Temperatrue
Probe
Connection
H: Cleanout
E: Drain
Valve
F: Drain Valve
Connection
J: Flue Outlet
G: Recirculation
Connection
D: T & P
Connection
G: Recirculation
Connection
Figure 51. Leakage Checkpoints
Read and understand this instruction
manual and the safety messages
herein before installing, operating or
servicing this water heater.
Failure to follow these instructions and
safety messages could result in death
or serious injury.
This manual must remain with the
water heater.
Never use this water heater unless it is completely filled with water.
To prevent damage to the tank, the tank must be filled with water.
Water must flow from the hot water faucet before turning “ON” gas
to the water heater.
A *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
B. *The anode rod fitting may be leaking.
C. Small amounts of water from temperature-pressure relief
valve may be due to thermal expansion or high water
pressure in your area.
D. *The temperature-pressure relief valve may be leaking at
the tank fitting.
E. Water from a drain valve may be due to the valve being
slightly opened.
F. *The drain valve may be leaking at the tank fitting.
G. Leakage from recirculation plug or pipe connection.
H. Leakage from the plug under the cleanout cover.
I. Leakage from the temperature probe connection (Not shown
in figure).
J. Condensate from the exhaust connection.
K. *The temperature probe fitting may be leaking.
Leakage from other water heaters, water lines, or ground seepage
should also be checked.
* To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet,
follow “Draining” instructions in the “Periodic Maintenance”
section and then remove fitting. Put pipe dope or teflon tape
on the threads and replace. Then follow the instructions in
WATER LEAK PROTECTION
The water heaters covered by this manual are able to support a water
leak detection feature that senses the buildup of water in vicinity of
the appliance, setting off an alarm to alert the end user.
To use this feature requires the installation of a kit. Contact your
local distributor or call Technical Support for assistance.
Kit number 100302557