41
Operating Set Point
120°F
Status: Heating
GAS
OFF
O
N
HELP
MENU
LCD Touch Display
Information
Display
Status Icons
Title Bar
Enable/Disable Switch*
Operational menus are multi functional.
* See the Features and
Components section of this
manual for the precise location.
Figure 45. User Interface Module (UIM) Desktop Screen
STATUS ICONS
The Status Icons are displayed on the Desktop screen and convey operational and diagnostic information. The icons are described
in the table below.
Table 11.
Status Icons
Icon
Description
Water temperature in the tank has fallen. Shaded area of the animated thermometer icon will rise and fall in response to
water temperature in the storage tank as sensed from the Temperature Probe. See
for location of the Temperature Probe.
Water temperature in the tank has reached the Operating Set Point. The control system enters the Standby mode.
The control is unable to initiate a heating cycle. This will happen whenever a Fault condition is detected by the control
system or when the Enable/Disable switch on front panel is in disable position. Display will read “Status: Water Heating
Disabled”.
Note:
When water heater is in disabled mode, a text message will appear next to the icon identifying cause
of disable mode.
The Combustion Blower is being energized.
The Spark Igniter is being energized. See
and
for location of the Spark Igniter.
GAS
OFF
O
N
The 24-volt gas valve is being energized.
The control system has sensed flame at the Main Burner from the flame sensor.
The control system has declared a Fault condition and must be inspected/serviced by a Qualified Service Agent. Fault
message details can be viewed in the Current Fault menu. Heating operation is disabled (lock out) until the condition that
caused the Fault is corrected. Power to the water heater must be cycled off and on at the breaker to reset the control
system.
Note:
Cycling power will not reset the control system if the condition that caused the Fault has not been corrected.
The control system has declared an Alert condition and must be inspected/serviced by a Qualified Service Agent. The
water heater will continue to operate during an Alert condition.